EasyManua.ls Logo

Xylem FLYGT P7030 Series - Page 25

Xylem FLYGT P7030 Series
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pump Approval
IEC
IECEx scheme
IEC 60079-0:2011, IEC 60079-1:2014; IEC 80079-36:2016; IEC 80079-37:2016
Ex db h IIB T3 Gb
FM (FM Approvals)
Explosion proof for use in Class I, Div. 1, Group C and D
Dust ignition proof for use in Class II, Div. 1, Group E, F and G
Suitable for use in Class III, Div. 1, Hazardous Locations
CSA Ex
Explosion proof for use in Class I, Div. 1, Group C and D
EN approval plate
This illustration describes the EN approval plate and the information that is contained in its
fields.
1. Approval
2. Approval authority and Approval
number
3. Approved drive unit
4. Cable entry temperature
5. Stall time
6. Starting current or Rated current
7. Duty class
8. Duty factor
9. Input power
10. Rated speed
11. Additional information
12. Maximum ambient temperature
13. Serial number
14. ATEX marking
15. Country of origin
IEC approval plate
This illustration describes the IEC approval plate and the information that is contained in its
fields.
International Norm; not for EU member countries.
1
2
3
5
6 7
8
9 10
11
12
13
14
4
WS001279D
15
1. Approval
2. Approval authority and Approval
number
3. Approved drive unit
4. Cable entry temperature
5. Stall time
6. Starting current or Rated current
7. Duty class
8. Duty factor
9. Input power
10. Rated speed
11. Additional information
12. Maximum ambient temperature
13. Serial number
14. ATEX marking
15. Country of origin
FM approval plate
This illustration describes the FM approval plate and the information that is contained in its
fields.
3 Product Description
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual 23