4. If zinc anodes are used, then remount them.
5.
Fasten the screws.
6.10 Replace the zinc anodes
1. Loosen the hexagonal screws securing the zinc anodes at the inlet.
WS003667A
2. Replace the zinc anodes and fasten the screws.
3. Loosen the hexagonal screws securing the anodes at the outlet.
WS003668A
4. Replace the zinc anodes and fasten the screws.
6.11 Service the pump
Type of
maintenance
Purpose Inspection interval
Initial inspection A Xylem-authorized personnel checks the pump
condition. From the results, the personnel
recommends the intervals for the periodical
inspection and overhaul for the installation.
Within the first year of operation.
6 Maintenance
76 P7030, P7035, P7040 Installation, Operation, and Maintenance Manual