EasyManua.ls Logo

Xylem FLYGT P7030 Series - Installation; Cable Requirements

Xylem FLYGT P7030 Series
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use appropriate personal protection equipment when working in or near open basins,
shafts, or trenches.
2
1
WS004361B
1. Fall protection harness
2. Anchoring point
Make sure that all safety guards are in place and secure, and that there is a suitable
barrier around the work area.
Wear clean slip-resistant shoes.
Make sure that any ladders or climbing equipment that is used is correctly sized and in
good working condition.
Never stand in coiled cables, ropes or wires, or between them and the open shaft or
basin.
WS004315C
Fasteners
Only use fasteners of the correct size and material.
Replace all corroded or damaged fasteners.
Make sure that all the fasteners are correctly tightened and that there are no missing
fasteners.
4.2 Cables
General requirements
The voltage drop in a long cable must be taken into account. Always follow the local
regulations for voltage drop.
If a Variable Frequency Drive (VFD) is used, then the screened cable must be used
according to the European CE and EMC requirements. For more information, contact a
sales or authorized service representative (VFD-supplier).
All unused conductors must be insulated.
The cable entry seal sleeve and washers must conform to the outside diameter of the
cable.
Cable condition
The cable must not have any sharp bends, and not be pinched.
4 Installation
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual 27

Table of Contents