EasyManua.ls Logo

Xylem FLYGT P7030 Series - Check the Impeller Rotation

Xylem FLYGT P7030 Series
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Screened cables
WS008809A
Screened SUBCAB - ground
Functional ground
Cable without sep. ground conductor
Ground conductor
is stranded ground cores
T1/T2 & T3/T4 (if applicable)
Twisted together
WH
shrink hose
GN/YE
shrink hose
L1 L2 L3 T1 T2 T3 T4 Bare wire
Figure 33: Cable without separate ground conductor. Ground conductor is stranded ground cores.
MiniCAS II
24 V AC/DC
R
CC
P
C
L2
L1
102
6
7 +T1
T15
T2
FLS10
5 -
11
1
12 VDC
9
8
10S
4
3
WS002623C
C Pump contactor
CC Control circuit
L1 Caution light (leakage)
L2 Caution light (stator over-
temperature)
P Pump main supply
R Reset switch
4.8 Check the impeller rotation
CAUTION: Crush Hazard
The starting jerk can be powerful. Make sure nobody is close to the unit when it is started.
If the propeller rotates in the wrong direction, then the pump lifts up and rotates, which can
damage the cables.
1. Start the motor.
2. Stop the motor after a few seconds.
3. Check the propeller rotation.
The correct direction of propeller rotation is clockwise when you look at the pump from
above.
4 Installation
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual 57

Table of Contents

Related product manuals