4.7.4 Sensor connection: MiniCAS
WS003843B
Color and marking of control leads
SUBCAB 4GX/7G and
SUBCAB
Control
Screenflex
SUBCAB AWG
Screened
T1
WH T1
OG
WH T1
T2
WH T2
BU
WH T2
T3
-
-
WH T3
T4
-
-
WH T4
Figure 25: Color and marking of control leads
See
Color code standard
on page 50.
Sensor terminal clamps
T1
T2
T14
T15
T16
T15
T16
Only valid for 7020, connection:
FLS+FLS+Thermal detectors+PT100
WS008805A
Figure 26: Sensor terminal clamps. Additional terminal clamps are shown at insert at lower right; only
valid for P7020, connection: FLS + FLS + thermal detectors + Pt100.
4.7.5 MiniCAS connections
FLS and thermal detectors
Thermal detector, Ohms Description
Overtemperature
1200 OK
430 Leakage
The values have a 10 % tolerance.
4 Installation
54 P7030, P7035, P7040 Installation, Operation, and Maintenance Manual

Table of Contents