Page 126 FT-2000D OPERATING MANUAL
104 rdSP SSB SHP
Function: Selects the passband characteristics of the DSP
filter for the SSB modes (LSB and USB).
Available Values: SOFt / ShAP
Default Setting: ShAP
SOFt (SOFT): Primary importance is attached to the
phase of the filter factor.
ShAP (SHARP): Primary importance is attached to the
amplitude of the filter factor.
105 rdSP SSB SLP
Function: Selects the shape factor of the DSP filter for
the SSB modes (LSB and USB).
Available Values: StP(STEEP) / nEd(MEDIUM) /
GEnt(GENTLE)
Default Setting: nEd (MEDIUM)
106 rdSP SSB NAR
Function: Selects the passband of the DSP filter for the
“Narrow” SSB mode.
Available Values: 200 / 400 / 600 / 850 / 1100 / 1350 /
1500 / 1650 / 1800 / 1950 / 2100 / 2250 Hz
Default Setting: 1800 Hz
SCOPE GROUP
ADVICE:
This group’s adjustment has no effect, if the optional DMU-
2000 Data Management Unit is not connected.
107 SCP 1.8 FIX
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 160 m amateur
band.
Available Values: 1.800 - 1.999 MHz (1 kHz/step)
Default Setting: 1.800 MHz
108 SCP 3.5 FIX
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 80 m amateur
band.
Available Values: 3.500 - 3.999 MHz (1 kHz/step)
Default Setting: 3.500 MHz
109 SCP 5.0 FIX
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 60 m amateur
band.
Available Values: 5.250 - 5.499 MHz (1 kHz/step)
Default Setting: 5.250 MHz
110 SCP 7.0 FIX
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 40 m amateur
band.
Available Values: 7.000 - 7.299 MHz (1 kHz/step)
Default Setting: 7.000 MHz
111 SCP 10.1 FIX
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 30 m amateur
band.
Available Values: (1)0.100 - (1)0.149 MHz (1 kHz steps)
Default Setting: (1)0.100 MHz