Page 61FT-2000D OPERATING MANUAL
IF NOISE BLANKER
(
NB
)
OPERATION
The FT-2000D includes an effective IF Noise Blanker, which can significantly reduce noise caused by automotive ignition
systems.
Main band
(
VFO-A
)
NB Operation
1. Press the
[
NB
]
button momentarily to reduce short-
duration pulse noise such as from switching transients,
automobile ignitions and power lines. The “ ” icon
will appear in the display to confirm that the Narrow-
NB is operating. Press and hold in the
[
NB
]
button for
two seconds to reduce longer-duration man-made pulse
noise. The “ ” icon will blink for five seconds, and
thereafter will appear continuously, to confirm that the
Wide-NB is operating.
2. Advance the
[
NB
]
knob to the point where the offend-
ing noise is best reduced or eliminated.
3. To end Noise Blanker operation, press the
[
NB
]
but-
ton once more. The “ ” icon will turn off, confirm-
ing that the Noise Blanker is no longer in operation.
ADVICE:
When you change the Noise Blanker level on the Main
(VFO-A) side, the Sub (VFO-B) band’s Noise Blanker
level will automatically change to be the same as that for
VFO-A, if the Sub (VFO-B) band’s Noise Blanker is en-
gaged.
Main Band
(
VFO-A
)
NB” Icon
[
B
]
Button
Sub Band
(
VFO-B
)
NB” Icon
[
NB
]
Button
I
NTERFERENCE
R
EJECTION
(
S
IGNALS
WITHIN
3
KHZ
)
[
NB
]
Knob
Sub band
(
VFO-B
)
NB Operation
1. Press the
[
B
]
button.
2. Within five seconds of pressing the
[
B
]
button (while
the imbedded orange LED is blinking), press the
[
NB
]
button momentarily to reduce short-duration pulse
noise such as from switching transients, automobile ig-
nitions and power lines. The “ ” icon will appear in
the display to confirm that the Narrow-NB is operat-
ing.
3. Within five seconds of pressing the
[
B
]
button (while
the imbedded orange LED is blinking), press and hold
in the
[
NB
]
button for two seconds to reduce longer-
duration man-made pulse noise. The “ ” icon will
blink for five seconds, then appear continuously, to con-
firm that the Wide-NB is operating.
4. To end Noise Blanker operation, press the
[
B
]
button,
then press the
[
NB
]
button. The “ ” icon will turn
off, confirming that the Noise Blanker is no longer in
operation.
ADVICE:
When you change the Noise Blanker level on the Sub
(VFO-B) side, the Main (VFO-A) band’s Noise Blanker
level will automatically change to be the same as that for
VFO-B, if the Main (VFO-A) band’s Noise Blanker is
engaged.