58
CHAPTER2 PROFIBUS Unit
2-10-5 WAIT
Function: Waits until the specified general-purpose input or memory input or serial
general-purpose input sets to the specified status.
Format: WAIT <DI or MI or SI No.> <Input status>
Example: WAIT 5,1
Waits until DI5 sets to ON.
Explanation: The WAIT command adjusts the timing according to the status of the
general-purpose input or memory input or serial general-purpose input.
(1) DI or MI or SI numbers
Specifies one from among the general-purpose inputs 0 - 15 (16
points)* or memory input 100 -147 (48 points) or the serial general-
purpose outputs 200- 231 (32 points).
(2) Input status
Here, “ 1” means the input is ON, and “0” means the input is OFF.
* 0 to 7 (8 points) for the SRCP/SRCD series controllers