8
ROBOT LANGUAGE
8-4 Robot Language Description
8-4-10
WAIT
Function: Waits until a specified general-purpose input or memory input changes
to a specified state.
Format: WAIT <DI or MI number>, <input status>
Example: WAIT 5, 1
Waits until DI5 turns on.
Explanation: This command adjusts the timing according to the general-purpose in-
put or memory input state.
(1) DI or MI number
Specify one
of the general-purpose input numbers from 0 to 15 (16
points) or memory input numbers from 100 to 147 (48 points).
(2) Input status
"1" means "on" and "0" means "off",
8-4-11 TIMR
Function: Waits for a specified amount of time before advancing to the next step.
Format: TIMR <time>
Example: TIMR 100
Moves to the next step after waiting one second.
Explanation: This command is used when adjusting the time within the program. Time
may be specified in lengths from 1 to 65535, in units of 10ms. In other
words, time may be specified from 0.01 seconds up to 655.35 seconds.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yamaha SRCD and is the answer not in the manual?

Yamaha SRCD Specifications

General IconGeneral
BrandYamaha
ModelSRCD
CategoryController
LanguageEnglish

Related product manuals