87
CHAPTER2 PROFIBUS Unit
(21) Addition of specified value to point variable P ................... Code 0115
The specified value is added to the point variable P.
Command option
QWn+22
QWn+20 QWn+18 QWn+16
QWn+14 QWn+12
Addition value
Command response
IWm+22
IWm+20 IWm+18 IWm+16
IWm+14 IWm+12
(Details)
Addition value:
A value of 1 to 999 can be specified.
(Example)
Transmission example 1:
10 is added to the point variable P.
QWn+22
QWn+20 QWn+18 QWn+16
QWn+14 QWn+12
QWn+10
QWn+8
0000
0000 0000
0000
0000 000A
0000 0115
Response example 1:
It is normally ended.
IWm+22
IWm+20 IWm+18 IWm+16
IWm+14 IWm+12
IWm+10
IWm+8
0000
0000 0000
0000
0000 0000
0000 0200