ENGINE REMOVAL
5-8
EAS30360
INSTALLING THE EXUP CABLES
1. Adjust:
EXUP servo motor pulley 1
▼▼▼ ▼▼▼▼▼ ▼▼▼ ▼▼▼ ▼▼▼▼▼
a. Connect the EXUP servo motor coupler to
the EXUP servo motor.
b. Activate the diagnostic mode and select the
diagnostic code number 53.
Refer to FUEL INJECTION SYSTEM on
page 8-33.
c. Set the engine stop switch to “”.
T
IP
Make sure that the EXUP servo motor pulley 1
is in the closed position as shown.
▲▲▲ ▲▲▲▲▲ ▲▲▲ ▲▲▲ ▲▲▲▲▲
2. Install:
EXUP cable 1 1
EXUP cable 2 2
▼▼▼ ▼▼▼▼▼ ▼▼▼ ▼▼▼ ▼▼▼ ▼▼▼
a. Install the EXUP cable 1 1 onto the servo
motor pulley, and then install the cable onto
the right side of the EXUP bracket.
T
IP
The correct installation position for the EXUP
cable 1 is identified by the casting mark a on
the EXUP servo motor.
EXUP cable 1 is identified by a black adjusting
bolt b.
▲▲▲ ▲▲▲▲▲ ▲▲▲ ▲▲▲ ▲▲▲ ▲▲▲
3. Adjust:
EXUP cables
Refer to ADJUSTING THE EXUP CABLES
on page 3-17.
7
4
3
17
16
18
8
9
2
1
13
11
12
14
15
15
6
10
20
19
21
5
1
2
1
A. EXUP servo motor pulley side
B. EXUP valve pulley side
1
2
1
2
a
A
b
B