EasyManua.ls Logo

Yamaha Vmax VMX17C 2009 - Troubleshooting

Yamaha Vmax VMX17C 2009
583 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRIC STARTING SYSTEM
8-10
EAS27190
TROUBLESHOOTING
The starter motor fails to turn.
T
IP
Before troubleshooting, remove the following part(s):
1. Top cover
2. Right side cover
NG
OK
NG
OK
OK
NG
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
1. Check the fuses.
(Main and ignition)
Refer to CHECKING THE FUS-
ES on page 8-125.
Replace the fuse(s).
2. Check the battery.
Refer to CHECKING AND
CHARGING THE BATTERY on
page 8-126.
Clean the battery terminals.
Recharge or replace the battery.
3. Check the starter motor operation.
Refer to CHECKING THE START-
ER MOTOR OPERATION on page
8-133.
Starter motor is OK. Perform the electric
starting system troubleshooting, starting
with step 5.
4. Check the starter motor.
Refer to CHECKING THE START-
ER MOTOR on page 5-46.
Repair or replace the starter motor.
5. Check the relay unit (starting circuit
cut-off relay).
Refer to CHECKING THE RE-
LAYS on page 8-129.
Replace the relay unit.
6. Check the relay unit (diode).
Refer to CHECKING THE RELAY
UNIT (DIODE) on page 8-130.
Replace the relay unit.
7. Check the starter relay.
Refer to CHECKING THE RE-
LAYS on page 8-129.
Replace the starter relay.
8. Check the main switch.
Refer to CHECKING THE
SWITCHES on page 8-121.
Replace the main switch.

Table of Contents