GENERATOR AND STARTER CLUTCH
5-42
3. Apply:
Sealant
(onto the crankshaft position sensor/stator
assembly lead grommet)
4. Install:
Stator coil
Crankshaft position sensor
Crankshaft position sensor/stator assembly
lead holder 1
T
IP
Route the crankshaft position sensor lead 1
to the inside of the rib a on the generator cov-
er.
Route the crankshaft position sensor lead un-
der the crankshaft position sensor/stator as-
sembly lead holder b.
Make sure that the crankshaft position sensor
lead is routed around the generator cover boss
c.
Route the stator coil lead 2 to the inside of the
rib d on the generator cover.
5. Install:
Generator cover gasket
Generator cover
T
IP
Tighten the generator cover bolts in stages and
in a crisscross pattern.
6. Install:
Generator cover plate damper
Generator cover plate 1
T
IP
Install the generator cover plate so that the let-
tering in the recycle mark a is right side up.
Tighten the generator cover plate bolts in stag-
es and in a crisscross pattern.
Sheave holder
90890-01701
Primary clutch holder
YS-01880-A
Yamaha bond No. 1215
90890-85505
(Three Bond No.1215®)
T
R
.
.
Stator coil bolt
10 Nm (1.0 m·kgf, 7.2 ft·lbf)
LOCTITE®
Crankshaft position sensor bolt
7 Nm (0.7 m·kgf, 5.1 ft·lbf)
LOCTITE®
Crankshaft position sensor/sta-
tor assembly lead holder 1 bolt
10 Nm (1.0 m·kgf, 7.2 ft·lbf)
LOCTITE®
2
1
3
T
R
.
.
Generator cover bolt
10 Nm (1.0 m·kgf, 7.2 ft·lbf)
LOCTITE®
T
R
.
.
Generator cover plate bolt
12 Nm (1.2 m·kgf, 8.7 ft·lbf)
1
a
b
c
d
2
A
A
New