User Constant Tables
5-51
U1-11
Shows output
on/off status.
(1-8)
− [Bit] A A 4AH
Output Term
Sts
U1-12
Inverter operat-
ing status
Inverter operating status.
Low/High register is changed by the
digital operator [DATA/ENTER] key.
Lower register(L) status
High register(H) status
− [Bit] A A 4BH
Int Ctl Sts
U1-13
Cumulative
operation time
Monitors the total operating time of the
Inverter. The initial value and the oper-
ating time/power on time selection can
be set in o2-07 and o2-08.
− 1H A A 4CH
Elapsed Time
U1-14
Software No.
(CPU)
(Manufacturer’s ID number) − [No.] A A 4DH
CPU Rev.
U1-15
Terminal AI1
input voltage
Monitors the input voltage of the multi-
function analog input 1.
10 V
0.01
%
AA 4EH
AI1 Input
U1-16
Terminal AI2
input voltage
Monitors the input voltage of the multi-
function analog input 2.
10 V
0.01
%
AA 4FH
AI2 Input
U1-17
Terminal AI3
input voltage
Monitors the input voltage of the multi-
function analog input 3.
10 V
0.01
%
A A 50H
AI3 Input
Constant
Number
Name
Description 100% Value
Min.
Unit
Control
Methods
MEMOBUS
Register
Display
Open-
loop
Vector
Flux
Vector
1: Multi-function on contact
output 1 (DO1) is on.
1: Multi-function on contact
output 2 (DO2) is on.
1: Multi-function on contact
output 3 (DO3) is on.
1: Multi-function on contact
output 4 (DO4) is on.
1: Multi-function on contact
output 5 (DO5) is on.
1: Multi-function on contact
output 6 (DO6) is on.
1: Multi-function on contact
output 7 (DO7) is on.
1: Multi-function on contact
output 8 (DO8) is on.
00000000
1: Run
1: Zero speed
1: Reverse
1: Reset signal input
1: Speed agree
1: Inverter ready
1: Minor fault
1: Major fault
00000000
1: Operation fault
1: Restarted after power loss
1: Remote operation
1: During regenarative
operation
Not Used (always 0)
1: During speed limit.
Not Used (always 0)
Not Used (always 0)
00000000