User Constant Tables
5-53
U1-42
Shows input on/
off status.
(9-16)
− [Bit] A A 69H
Input Sts(9-16)
U1-43
Shows input on/
off status.
(17-20)
− [Bit] A A 6AH
Input Sts(17-
20)
U1-46
Superior com-
mand 1
The operation command lower byte
from PLC
−−A A 6DH
Superior Cmd 1
U1-47
Superior com-
mand 2
The operation command high byte from
PLC
−−AA 6EH
Superior Cmd 2
U1-48
External torque
reference
Monitors the external torque reference. Motor rated torque
0.01
%
AA 6FH
Torque Refer-
ence
U1-49
Output zero-
voltage
Monitors the output zero-voltage value
in the Inverter.
−
1 V
A A 70H
Output Zero V
U1-51
Input torque
compensation
Monitors the Input torque compensa-
tion.
Motor rated torque
0.01
%
No A 72H
Input T-Cmp
U1-52
Slip frequency
reference
Monitors the slip frequency reference. Motor rated slip
0.01
%
A A 73H
Slip Reference
U1-53
Magnetic flux
reference
Monitors the magnetic flux reference. Motor no-load current
0.01
%
A A 74H
Mag-flux Ref.
U1-54
Power supply
descent value
Not used. −
0.01
%
A A 75H
Power Descent
U1-55
Motor tempera-
ture
Not used. − 1°CA A 76H
Motor Temp.
Constant
Number
Name
Description 100% Value
Min.
Unit
Control
Methods
MEMOBUS
Register
Display
Open-
loop
Vector
Flux
Vector
1: Input terminal S9 is on.
1: Input terminal S10 is on.
1: Input terminal S11 is on.
1: Input terminal S12 is on.
1: Input terminal S13 is on.
1: Input terminal S14 is on.
1: Input terminal S15 is on.
1: Input terminal S16 is on.
00000000
1: Input terminal S17 is on.
1: Input terminal S18 is on.
1: Input terminal S19 is on.
1: Input terminal S20 is on.
Not Used (always 0)
Not Used (always 0)
Not Used (always 0)
Not Used (always 0)
00000000