5-32
Multi-function Analog Input Functions
Note Set to 0F when the analog input is used for the built-in PLC or not used as multi-function contact input.
Setting
Value
Function Contents (100%)
Control Methods
Open-
loop
Vector
Flux
Vector
00
Auxiliary frequency reference (Can be set
only for H3-09)
Maximum number of rotations Yes Yes
01 Frequency gain Frequency reference command value Yes Yes
02 Frequency bias Maximum number of rotations Yes Yes
05
Accel/decel time changes (reduction
coefficient)
Set acceleration and deceleration times Yes Yes
06 DC injection braking current Inverter rated current Yes No
07 Overtorque detection level Motor rated torque Yes Yes
09 Frequency reference lower limit level Maximum number of rotations Yes Yes
0A Jump frequency Maximum number of rotations Yes Yes
0F
Not used (Set when the terminal is used
for the built-in PLC or not used)
− Yes Yes
10 Positive torque limit Motor rated torque Yes Yes
11 Negative torque limit Motor rated torque Yes Yes
12 Regenerative torque limit Motor rated torque Yes Yes
13
Torque reference at torque control/Torque
limit at speed control
Motor rated torque No Yes
14 Torque compensation Motor rated torque No Yes
15 Positive/negative torque limit Motor rated torque Yes Yes
1F
(For H3-09 and H3-13) Analog input not
used
−
Yes Yes
(For H3-05) Frequency reference Maximum number of rotations