EasyManua.ls Logo

YASKAWA G7 - Page 57

YASKAWA G7
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57
Table 4.7 “D” Parameters
Access Level
Name
Address Description Data
Range Unit Default
During
Run
V/f
V/f
w/PG
OLV
FV OLV2
d1-01 0280h Frequency Reference 1 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-02 0281h Frequency Reference 2 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-03 0282h Frequency Reference 3 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-04 0283h Frequency Reference 4 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-05 0284h Frequency Reference 5 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-06 0285h Frequency Reference 6 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-07 0286h Frequency Reference 7 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-08 0287h Frequency Reference 8 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-09 0288h Frequency Reference 9 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-10 028Bh Frequency Reference 10
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-11 028Ch Frequency Reference 11
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-12 028Dh Frequency Reference 12
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-13 028Eh Frequency Reference 13
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-14 028Fh Frequency Reference 14
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-15 0290h Frequency Reference 15
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-16 0291h Frequency Reference 16
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-17 0292h Jog Frequency Reference
0.0 ~ 400.0 Hz 0.01 Hz 6.0 Hz R Q Q Q Q Q
d2-01 0289h
Frequency Reference
Upper Limit
0.0 ~ 110.0 % 0.1 % 100.0 % A A A A A
d2-02 028Ah
Frequency Reference
Lower Limit
0.0 ~ 110.0 % 0.1 % 0.0 % A A A A A
d2-03 0293h
Analog Input Frequency
Reference Lower Limit
0.0 ~ 110.0 % 0.1 % 0.0 % A A A A A
d3-01 0294h Jump Frequency 1 0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A A A A
d3-02 0295h Jump Frequency 2 0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A A A A
d3-03 0296h Jump Frequency 3 0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A A A A
d3-04 0297h Jump Bandwidth 0.0 ~ 20.0 Hz 0.1 Hz 1.0 Hz A A A A A
0 Disabled
d4-01 0298h
MOP Reference Memory
Selection
1 Enabled
1 0 A A A A A
d4-02 0299h Trim Control Level 0 ~ 100 % 1 % 10 % A A A A A
0 Speed Control
d5-01 029Ah Torque Control Selection
1 Torque Control
1 ms 0 ms A A
d5-02 029Bh
Torque Reference Filter
Time
0 ~ 1000 ms 1 ms Cntrl Meth
A A
1 Soft Starter Output
d5-03 029Ch Speed Limit Selection
2 d5-04 Setting
1 1 A A
d5-04 029Dh Speed Limit Value -120 ~ 120 % 1 % 0 % A A
d5-05 029Eh Speed Limit Bias 0 ~ 120 % 1 % 10 % A A
d5-06 029Fh
Speed/Torque
Changeover Hold Time
0 ~ 1000 ms 1 ms 0 ms A A
0 Disabled
d5-07 02A6h
Directional Speed Limit
Selection
1 Enabled
1 1 A
d6-01 02A0h Field-Weakening Level
0 ~ 100 % 1 % 80 % A A
d6-02 02A1h
Field-Weakening
Frequency
0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A
0 Disabled
d6-03 02A2h Field Forcing Selection
1 Enabled
1 0 A A A
d6-05 02A4h AR Time Gain 0.0 ~ 10.0 0.01 1 A
d6-06 02A5h Field Forcing Limit 100 ~ 400 % 1 % 400 % A A A

Other manuals for YASKAWA G7