57
Table 4.7 “D” Parameters
Access Level
Name
Address Description Data
Range Unit Default
During
Run
V/f
V/f
w/PG
OLV
FV OLV2
d1-01 0280h Frequency Reference 1 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-02 0281h Frequency Reference 2 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-03 0282h Frequency Reference 3 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-04 0283h Frequency Reference 4 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R Q Q Q Q Q
d1-05 0284h Frequency Reference 5 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-06 0285h Frequency Reference 6 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-07 0286h Frequency Reference 7 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-08 0287h Frequency Reference 8 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-09 0288h Frequency Reference 9 0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-10 028Bh Frequency Reference 10
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-11 028Ch Frequency Reference 11
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-12 028Dh Frequency Reference 12
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-13 028Eh Frequency Reference 13
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-14 028Fh Frequency Reference 14
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-15 0290h Frequency Reference 15
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-16 0291h Frequency Reference 16
0.0 ~ 400.0 Hz 0.01 Hz 0.0 Hz R A A A A A
d1-17 0292h Jog Frequency Reference
0.0 ~ 400.0 Hz 0.01 Hz 6.0 Hz R Q Q Q Q Q
d2-01 0289h
Frequency Reference
Upper Limit
0.0 ~ 110.0 % 0.1 % 100.0 % A A A A A
d2-02 028Ah
Frequency Reference
Lower Limit
0.0 ~ 110.0 % 0.1 % 0.0 % A A A A A
d2-03 0293h
Analog Input Frequency
Reference Lower Limit
0.0 ~ 110.0 % 0.1 % 0.0 % A A A A A
d3-01 0294h Jump Frequency 1 0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A A A A
d3-02 0295h Jump Frequency 2 0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A A A A
d3-03 0296h Jump Frequency 3 0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A A A A
d3-04 0297h Jump Bandwidth 0.0 ~ 20.0 Hz 0.1 Hz 1.0 Hz A A A A A
0 Disabled
d4-01 0298h
MOP Reference Memory
Selection
1 Enabled
1 0 A A A A A
d4-02 0299h Trim Control Level 0 ~ 100 % 1 % 10 % A A A A A
0 Speed Control
d5-01 029Ah Torque Control Selection
1 Torque Control
1 ms 0 ms A A
d5-02 029Bh
Torque Reference Filter
Time
0 ~ 1000 ms 1 ms Cntrl Meth
A A
1 Soft Starter Output
d5-03 029Ch Speed Limit Selection
2 d5-04 Setting
1 1 A A
d5-04 029Dh Speed Limit Value -120 ~ 120 % 1 % 0 % A A
d5-05 029Eh Speed Limit Bias 0 ~ 120 % 1 % 10 % A A
d5-06 029Fh
Speed/Torque
Changeover Hold Time
0 ~ 1000 ms 1 ms 0 ms A A
0 Disabled
d5-07 02A6h
Directional Speed Limit
Selection
1 Enabled
1 1 A
d6-01 02A0h Field-Weakening Level
0 ~ 100 % 1 % 80 % A A
d6-02 02A1h
Field-Weakening
Frequency
0.0 ~ 400.0 Hz 0.1 Hz 0.0 Hz A A
0 Disabled
d6-03 02A2h Field Forcing Selection
1 Enabled
1 0 A A A
d6-05 02A4h AR Time Gain 0.0 ~ 10.0 0.01 1 A
d6-06 02A5h Field Forcing Limit 100 ~ 400 % 1 % 400 % A A A