B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide 213
Parameter Table
B
Note: Fault trace (i.e., the fault history) is not maintained when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or
Uv3 occur.
U4-31
Car Acceleration Rate
Shows the car acceleration rate.
No signal output
available
0.01 m/
s
2
U4-40
Speed Reference Limit
at Rescue Operation
Displays the speed limit for Rescue Operation based on how much power the
backup battery or UPS has. Displays 0% when Rescue Operation is not being
performed.
No signal output
available
1%
U4-42
<35>
Remaining Distance Displays the remaining distance according to the stopping method selected.
10 V:
S5-10 = 1: S5-11
S5-10 = 2: S5-12
1 mm
U4-43
<35>
Minimum Deceleration
Distance
Displays the Minimum Deceleration Distance calculated by E1-04.
No signal output
available
1 mm
U4-44
<35>
Minimum Stop
Distance
Displays the Minimum Stop Distance calculated by d1-26.
No signal output
available
1 mm
<29> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or
5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.
<35> o1-12 (Length Units) determines the units. When o1-12 is set to 0, the unit is millimeters. When o1-12 is set to 1, the unit is inch.
<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are
checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192 × drive’s
rated current (A), from the condition “8192 (maximum value) = drive’s rated current (A)”.
<41> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 0099H.
<42> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 009BH.
No. Name Description
Analog Output
Level
Unit
TOEP_C710616_38H_7_0.book 213 ージ 015年11月11日 水曜日 午後7時40