EasyManua.ls Logo

YASKAWA L1000A - D: Speed References

YASKAWA L1000A
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide 173
Parameter Table
B
d: Speed References
Speed Reference parameters are used to set the various speed reference values during operation.
d1: Speed Reference
No. Name Description Setting
d1-01
Speed Reference 1
Sets the Speed reference for the drive when d1-18 is set to 0 or 3. Setting units are
determined by parameter o1-03.
Default: 0.00%
<6>
Min: 0.00%
Max: 100.00% <6>
d1-02
Speed Reference 2
d1-03
Speed Reference 3
d1-04
Speed Reference 4
d1-05
Speed Reference 5
d1-06
Speed Reference 6
d1-07
Speed Reference 7
d1-08
Speed Reference 8
d1-18
Speed Reference Selection
Mode
Sets the mode of speed reference selection by digital inputs.
0: Use multi-speed references (d1-01 to d1-08)
1: High speed reference has priority (d1-19 to d1-23, d1-26)
2: Leveling speed reference has priority (d1-19 to d1-23, d1-26)
3: Use multi-speed references d1-02 to d1-08, no speed selection stops the drive.
Drive will stop when all input terminals programmed for speed references (H1- =
3, 4, 5) are open.
Default: 0
Min: 0
Max: 3
d1-19
Nominal Speed Sets the nominal speed reference when d1-18 = 1 or 2.
Default:
100.00%
<6>
Min: 0.00%
Max: 100.00% <6>
d1-20
Intermediate Speed 1 Sets intermediate speed reference 1 when d1-18 = 1 or 2.
Default: 0.00%
<6>
Min: 0.00%
Max: 100.00%
<6>
d1-21
Intermediate Speed 2 Sets intermediate speed reference 2 when d1-18 = 1 or 2.
Default: 0.00%
<6>
Min: 0.00%
Max: 100.00% <6>
d1-22
Intermediate Speed 3 Sets intermediate speed reference 3 when d1-18 = 1 or 3.
Default: 0.00%
<6>
Min: 0.00%
Max: 100.00% <6>
d1-23
Releveling Speed Sets speed reference for releveling when d1-18 = 1 or 2.
Default: 0.00%
<6>
Min: 0.00%
Max: 100.00%
<6>
d1-24
Inspection Operation
Speed
Sets speed reference when inspection operation is enabled.
Default:
50.00%
<6>
Min: 0.00%
Max: 100.00% <6>
TOEP_C710616_38H_7_0.book 173 ージ 015年11月11日 水曜日 午後7時40

Table of Contents

Other manuals for YASKAWA L1000A