4 Specifications and Dimensional Drawings of Cables and Peripheral Devices
4.4.6 Noise Filter
4-14
(1) Single-phase, 100/200 V
Model FN2070-6/07 FN2070-10/07 FN2070-16/07
Dimensional
Drawings
External
Dimensions in
mm (in)
Tolerance Dimensions
A
-
113.5±1
(4.47±0.039)
156±1
(6.14±0.039)
119±0.5 (4.69±0.020)
B
±1 (±0.039) 57.5 (2.26) 85.5 (3.37)
C
- 45.4±1.2 (1.79±0.047) 57.6±1 (2.27±0.039)
D
±1 (±0.039) 94 (3.70) 130.5 (5.14) 98.5 (3.88)
F
±0.3 (±0.012) 103 (4.06) 143 (5.63) 109 (4.29)
J
±0.2 (±0.0079) 25 (0.98) 40 (1.57)
K
±0.5 (±0.020) 8.4 (0.33) 8.6 (0.34)
L
±0.5 (±0.020) 32.4 (1.28) -
M
±0.1 (±0.039) 4.4 (0.17) 5.3 (0.21) 4.4 (0.17)
N
±0.1 (±0.039) 6 (0.24) 7.4 (0.29)
P
±0.1 (±0.039) 0.9 (0.035) 1.2 (0.047)
Q
±0.3 (±0.012) - 66 (2.60)
R
±0.2 (±0.0079) - 51 (2.01)
S
±0.5 (±0.020) 38 (1.50) -
Specifications
250 VAC, 6 A 250 VAC, 10 A 250 VAC, 16 A
Applicable
SERVOPACK
SGDS-
Single-phase
100 V
A5F
02F 04F
01F
Single-phase
200 V
A5A
04A 08A01A
02A
S
Side view
Top view
J
L
P
C
K
M
B
N
A
D
F
Side view
Top view
J
K
C
P
N
R
Q
B
M
A
D
F
Contact Terminal
P/N/E
140
-0
+5

Table of Contents