4.4 Peripheral Devices
4-15
(2) Three-phase, 200 V
Select one of the following noise filters according to SERVOPACK capacity. For more details on selecting
current capacity for a noise filter, refer to 2.5.3 Noise Filters, Magnetic Contactors, Surge Protectors and AC/DC
Reactors.
For connecting the noise filter, refer to 5.1.3 Typical Main Circuit Wiring Examples.
Dimensions in mm (in) Model
Tolerance FN258L-7/07 FN258L-16/07
A ±1 (±0.039) 255 (10.04) 305 (12.01)
B - 126±0.8 (4.96±0.031) 142±0.8 (5.59±0.031)
C ±0.6 (±0.024) 50 (1.97) 55 (2.17)
D - 225±0.8 (8.86±0.031) 275±0.8 (10.83±0.031)
E ±0.5 (±0.020) 240 (9.45) 290 (11.42)
F ±0.3 (±0.012) 25 (0.98) 30 (1.18)
G ±0.2 (±0.0079) 6.5 (0.26)
H ±10 (±0.39) 300 (11.81)
J-1±0.1 (0.039±0.0039)
L ±1 (±0.039) 9 (0.35)
O- M5
P- AWG16 AWG14
Specifications
480 VAC, 7 A 480 VAC, 16 A
Applicable Three-phase
200 V
05A 10A
Side view
Front/Side view
7A to 55A
G
P
B
O
E
A
DH
L
C
F
J

Table of Contents