EasyManua.ls Logo

YASKAWA SOLECTRIA XGI 1500 Series - User Manual

YASKAWA SOLECTRIA XGI 1500 Series
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Commercial 1500VDC String Inverter
SOLECTRIA XGI 1500
Installation and Operation Guide
Models: XGI 1500-125/125 XGI 1500-125/150
XGI 1500-150/166 XGI 1500-166/166

Table of Contents

Questions and Answers

  • J
    Joy RobinsonSep 23, 2025
    What to do if AC high frequency 1 is detected on my YASKAWA SOLECTRIA XGI 1500 Inverter?
    • D
      Diane NelsonSep 23, 2025
      Using a CAT III multi-meter verify the AC frequency. If there is a discrepancy of greater than 2% between the measured results and the frequency detected, contact Technical Support.
  • D
    David PittmanAug 23, 2025
    What to do if an ARC fault is detected in my YASKAWA SOLECTRIA XGI 1500?
    • T
      Teresa MunozAug 23, 2025
      If a DC series arc fault has been detected in the PV array, inspect for and repair damage to the PV array and DC wiring. Clear the ARC Fault and retest. If the inverter doesn’t clear the error, contact Technical Support.
  • R
    Robert HoweAug 25, 2025
    Why is there excessive leakage current in my YASKAWA SOLECTRIA XGI 1500 Inverter?
    • C
      Christopher DanielAug 26, 2025
      Excessive leakage current indicates a ground fault condition where the leakage current is greater than the allowable limit. Check the array for an unintentional reference to ground.
  • C
    Carla AndersonAug 27, 2025
    What to do if islanding is detected in my YASKAWA SOLECTRIA XGI 1500?
    • M
      Mr. Tony SchultzAug 27, 2025
      If an islanding condition has been detected, the inverter will cease production until the event has ended. Using a CAT III multi-meter, verify the AC voltage. If an islanding condition (no AC voltage) is identified, check all AC fuses or breakers.
  • E
    Ethan SuttonAug 27, 2025
    What does it mean when the isolation resistance is low in my YASKAWA Inverter?
    • J
      Jerome VargasAug 27, 2025
      Low isolation resistance indicates a ground fault condition where the insolation resistance between the DC conductors and ground is below the allowable limit. Check the array for an unintentional reference to ground.
  • R
    russell99Sep 16, 2025
    What to do if a communication fault initialization fault occurs on my YASKAWA SOLECTRIA XGI 1500?
    • G
      Glenda ShafferSep 16, 2025
      Power cycle the inverter. If the inverter doesn’t clear the error, contact Technical Support.
  • B
    Brenda Barry DDSSep 13, 2025
    What to do if communication failure 1 occurs on my YASKAWA SOLECTRIA XGI 1500 Inverter?
    • D
      Daniel LucasSep 13, 2025
      Power cycle the inverter. Contact Technical Support.
  • R
    Robert EstradaSep 15, 2025
    What to do if communication failure 2 occurs on my YASKAWA Inverter?
    • C
      Carla WestSep 15, 2025
      Power cycle the inverter. Contact Technical Support.
  • A
    Ashley CollinsSep 5, 2025
    What to do if there is an internal over current or over voltage in my YASKAWA Inverter?
    • M
      Michelle WalkerSep 6, 2025
      Power cycle the inverter. If the inverter doesn’t clear the error, contact Technical Support.
  • S
    Stephen RodriguezSep 3, 2025
    What to do if the operational self-check fails on my YASKAWA Inverter?
    • P
      Patricia ThompsonSep 3, 2025
      If the inverter self-diagnostic check has failed during operation, power cycle the inverter. If the inverter doesn’t clear the error, contact Technical Support.

YASKAWA SOLECTRIA XGI 1500 Series Specifications

General IconGeneral
CategoryInverter
ModelXGI 1500 Series
TypeGrid-tied
Maximum AC Power Output1500 kVA
Max. AC Output Power1500 kVA
Max. DC Input Voltage1500 VDC
AC Output Voltage600 VAC
Output Voltage600 VAC
Operating Temperature Range-20°C to +50°C
Operating Temperature-20°C to +50°C
Storage Temperature-40°C to +70°C
Protection FeaturesDC Overvoltage, DC Overcurrent, AC Overvoltage, AC Overcurrent, Ground Fault, Anti-Islanding
Communication InterfaceEthernet, Modbus TCP
Humidity0-95% non-condensing
Enclosure RatingNEMA 3R
Output Power1500 kVA