User Constant Tables
5-49
îš„ Multi-function Contact Outputs: H2
User constants for multi-function outputs are shown in the following tables.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
H2-01
Terminal M1-
M2 function
selection
(contact)
Multi-function contact output 0 to 37 0 No A A A A A 40BH -
Term M1-M2
Sel
H2-02
Terminal P1
function
selection
(open collec-
tor)
Multi-function contact output
1
0 to 37 1 No A A A A A 40CH -
Term P1 Sel
H2-03
Terminal P2
function
selection
(open collec-
tor)
Multi-function contact output
2
0 to 37 2 No A A A A A 40DH -
Term P2 Sel
H2-04
Terminal P3
function
selection
(open collec-
tor)
Multi-function contact output
3
0 to 37 6 No A A A A A 40EH -
Term P3 Sel
H2-05
Terminal P4
function
selection
(open collec-
tor)
Multi-function contact output
4
0 to 37 10 No A A A A A 40FH -
Term P4 Sel