Fig. 4.4 Example of 1st RS232C Interface
1. Use 1st RS232Cinterface when the built-in
type tape reader (PTR) is used.
In this case, RS232C interface freely usable
by customers is 2nd RS232C interface only.
2. Keep cable length from tape reader to main
board (JANCD-MB20Type) less than 3m. Contact
YASREPin advance if it is necessary to exceed
3m.
4.2.3 ALARM170, 172, 173, 174 AND175 (Memory
Error)
170:
172:
173:
174:
175:
HEMERROR(OFS)
Tool offset value total check error
MEtlERROR(SET)
Setting area total check error
MEMERROR(PRM)
Parameter area total check error
MEMERROR(KEEP)
Keep memory total check error
MEMERROR(MACR)
Macro total check error
These alarms indicate that tool offset value,
setting data, parameters, keep memorydata
and/or macro data were rewritten for some
reason.
The following points may be considered as
their cause.
. Failure of battery unit (battery alarm
display)
JANCD-MB20module,
-MM20module or -MM21
module (optional) is not correctly connected.
Failure of above modules
Contact YASREPin any of above cases,