8. NC DATAHANDLING
8.1 !5YSTEMNO. SETTING(#6219)
Set system No. at
“1” to write parameter
number. System number can be set by setting
the value of #6219 through the operator’s
panel.
(1) Setting of #6219
‘on :
SYSTEM
For normal operation.
Writing parameters is
prevented.
Wn
1:
PARAMETER
To write parameters.
At this position, Cycle
start is prevented.
Wn
4:
TEST (0) (Maintenance mode)
Normal operation is similar to the case of “O”
SYSTEM,but available only for maintenance
tiode.
Note:
1. Setting values other than those described
above will prevent correct operation.
2.
~ettingcan be effective only when thesys-
tem number switch provided on the control
unit main module (IIB20) is set at”(l. “
Refer to Par. 7, ‘SETTINGANDADJUSTMENT
FORMODULE.“
(2) Alarm Display of System No. Setting (#6219)
Whensetting #6219 is Set at”l”, cycle
Start is prohibited, causing unexpected errors.
To prevent this, alarm status is displayed
if #6219 is set at a value other than “O.”
ALARM
01234 NOO03
SYSTEMNO. SETTING(#6219) : (11
MESSAGE
LSK
Fig. 8.1 Typical Alarm Display
System number #6219 should be set at ‘Cl”
except for writing parameters.
8.2 DISPLAYINGANDWRITINGPARAMETERS
This system has various parameters stored in
memory.
They determine operating conditions
such as tape coding and feedrate.
The para-
meters can always be displayed regardless of
the mode even during automatic operaticm.
For details, see Par. 9.4, ‘LIST OF PAF!AMETER
NUMBERS.“ For sequence parameters #7000 to
#7099, see machine tool builder’s manual.
–fjo–