4.3.7 MANUALRAPIDMODEOPERATIONFAULTY
Trouble
Rapid mode not select-
ed.
Axial direction not
specified.
Rapid override not
entered.
Parameter not set cor-
rectly.
Not at machine lock.
Check Procedure
m#1300 DO
+X~#1302 Dz
–X~#1302 DS
+Zm#1302 D4
–Zm#1302 D5
Input status and Rapid feedrate
MNSlzol
Inputstatus
Rapidfeedrate
ROV2Rovl Xaxis Zaxis
; ; [SF+ r!F+
0,’ ,E!ng lx+ [=n’1“+
0 [01 F. (*6231 Setting speed)
Notes: 1) 1: close O: open
2) The following table is applied for rapid
override at 6 step specification.
(6 step specification: Parameter u6018 Dz=l)
Input status
Rapid feedrate
ROV4 ROV2 ROV1
X axis Z axis
1
0 1 100% 100%
1
0 0
50% 50%___
o
1
25%
25% _
o 1 A
10%
lo%__
o 0 1
5%
L—+
o 0
0 FO
(!6231 Setting speed) --
1: close O: open
Check following parameters for correct
setting as shown in the above table.
#6280 X-axis rapid feedrate
#6281 Z-axis rapid feedrate
#6231 Rate at FO specification
~#1303 DI
Solution
Select the mode.
Check wiring.
Select axial direction.
Check wiring.
Select rapid override and
set the parameter.
Check the switch.
iTliiJt6000D, notatl.
–33–