Appendix
283
0-Disabled (power indicator LED does not
flash)
1-Enabled (power indicator LED fast flashes
(300ms) green)
Example
phone_setting.ring_power_led_flash_enable
= 1
Parameter-
phone_setting.mail_power_led_fl
ash_enable
Configuration File
<y0000000000xx>.cfg
Description
Enables or disables the power indicator LED
to flash when the phone receives a voice
mail or a text message.
If it is set to 0, the status of the power
indicator LED is determined by the value of
the parameter
“phone_setting.common_power_led_enable
.
Format
Boolean
Default Value
0
Range
Valid values are:
0-Disabled (power indicator LED does not
flash)
1-Enabled (power indicator LED slow flashes
(1000ms) green)
Example
phone_setting.mail_power_led_flash_enable
= 0
Parameter-
phone_setting.mute_power_led_
flash_enable
Configuration File
<y0000000000xx>.cfg
Description
Enables or disables the power indicator LED
to flash when a call is mute.
If it is set to 0, the status of the power
indicator LED is determined by the value of
the parameter
“phone_setting.common_power_led_enable”
.