Call Features
360
Permitted
Values
String within 16 characters
Default
Blank
Web UI
Settings > Dial Plan > Area Code > Code
Parameter
dialplan.area_code.min_len <y0000000000xx>.cfg
Description
It configures the minimum length of the entered number.
Note: It works only if “dialplan.digitmap.enable” and “account.X.dialplan.digitmap.enable” are set to 0
(Disabled).
Permitted
Values
Integer from 1 to 15
Default
1
Web UI
Settings > Dial Plan > Area Code > Min Length (1-15)
Parameter
dialplan.area_code.max_len <y0000000000xx>.cfg
Description
It configures the maximum length of the entered number.
Note: The value must be larger than the minimum length. It works only if “dialplan.digitmap.enable
and “account.X.dialplan.digitmap.enable” are set to 0 (Disabled).
Permitted
Values
Integer from 1 to 15
Default
15
Web UI
Settings > Dial Plan > Area Code > Max Length (1-15)
Parameter
dialplan.area_code.line_id <y0000000000xx>.cfg
Description
It configures the desired line to apply the area code rule. The digit 0 stands for all lines. If it is left
blank, the area code rule will apply to all lines on the IP phone.
Note: Multiple line IDs are separated by commas. It works only if “dialplan.digitmap.enable and
“account.X.dialplan.digitmap.enable” are set to 0 (Disabled).
Permitted
Values
0 to 16 (for T57W/T54W/T48U/T48S/T48G/T46U/T46S/T46G/T29G)
0 to 12 (for T53W/T53/T43U/T42U/T42S/T42G)
0 to 6 (for T41P/T41S/T27G)
0 to 4 (for T33P/T33G)
0 to 3 (for T40P/T40G/T23P/T23G)
0 to 2 (for T31P/T31G/T31/T21(P) E2)
0, 1 (for T30P/T30/T19(P) E2/CP920)
Default
Blank
Web UI
Settings > Dial Plan > Area Code > Account
Block Out Configuration
The following table lists the parameters you can use to configure the block out.
Parameter
dialplan.block_out.number.X
[1]
<y0000000000xx>.cfg
Description
It configures the block out numbers.

Table of Contents

Other manuals for Yealink SIP-T31G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T31G and is the answer not in the manual?

Yealink SIP-T31G Specifications

General IconGeneral
Mounting kitYes
Number of handles included1 pc(s)
Display diagonal2.3 \
Display resolution132 x 64 pixels
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Voice codecsG.722, G.729, AGC, G.729A, AJB, PLC, G.711Mu, VAD, G.711a, G.723.1, G.726, iLBC, CNG, OPUS
AC adapter input voltage100 - 240 V
AC adapter output current0.6 A
AC adapter output voltage5 V
Power consumption (typical)3 W
Lines quantity2 lines
Phonebook capacity1000 entries
Number of VoIP accounts2
Sustainability certificatesRoHS, REACH
Networking standardsIEEE 802.3af, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1x
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN interface typeGigabit Ethernet
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorGray
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Depth189 mm
Width188 mm
Height162 mm
Package depth210 mm
Package width213 mm
Package height103 mm

Related product manuals