EasyManua.ls Logo

Yeswelder Firstess DP200 - Installations

Yeswelder Firstess DP200
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standard Voltage
/Frequency
240V±10%
50/60Hz
120V±10%
50/60Hz
Input Current
I1 max=35A
I1 eff=17.4A
I1 max=40A
I1 eff=20A
INPUT-SINGLEPHASEONLY
RATEDOUTPUT-DCONLY
OUTPUT RANGE
OTHER PARAMETERS
PACKING DIMENSIONS
TEMPERATURERANGE
Voltage
240V
120V
Mode
GMAW
(MIG)
SMAW
(STICK)
GTAW
(TIG)
Duty Cycle
25%
60%
Current
200A
130A
200A
130A
180A
117A
120A
78A
120A
78A
120A
78A
VoltsatRated
Current
24V
20.5V
18V
15.2V
27.2V
24.7V
20V
17.9V
14.8V
13.2V
24.8V
23.2V
Voltage
240V
120V
Mode
GMAW
SMAW
GTAW
GMAW
SMAW
GTAW
Open Circuit
Voltage
81V
Welding
Current Range
30A~200A
10A~180A
10A~200A
30A~140A
10A~120A
10A~120A
Welding
VoltageRange
15.5V~24V
20.4V~27.2V
10.4V~18V
15.5V~21V
20.4V~24.8V
10.4V~14.8V
Machine
PowerFactor
Efficiency
ProtectionClass InsulationClass
0.8
≥80%
IP21S F
DP200
Machine
Length
Width
Height Weight
21.3" 14.9" 17.9"
44.86lb
OperatingTemperatureRange
-20°C~+50°C(-4°F~122°F)
StorageTemperatureRange
-20°C~+50°C(-4°F~122°F)
TECHNICAL SPECIFICATIONS: DP200
1. SAFETY
Read the entire installation section before you start
the installation.
INSTALLATION
WARNIG
ELECTRIC SHOCK can kill.
Ÿ Only qualified personnel should per-
form this installation.
Ÿ Only personnel reading and under-
standing the DP200 Operator’s Manual
should install and operate this equip-
ment.
Ÿ The machine must be plugged into a grounded receptacle
per national, local, or other applicable electrical codes.
Ÿ The DP200 power switch should be in the OFF(“O”) posi-
tion when installing the work cable and gun and connect-
ing the power cord to input power.
SELECT SUITABLE LOCATION
STACKING
Locate the DP200 in a dry place with free clean air circulation
to minimize the chance of dirt accumulation that can block air
passages and cause overheating.
DP200 cannot be stacked.
TILTING
The machine should be placed on a secure, level surface or a
recommended cart. The equipment may topple over if this re-
quirement is not followed.
- 5 -
DP200
100%
100A
19V
100A 14V
90A 23.6V
60A 17V
60A 12.4V
60A 22.4V
SMAW
(STICK)
GTAW
(TIG)
GMAW
(MIG)
25%
60%
100%
25%
60%
100%
25%
60%
100%
25%
60%
100%
25%
60%
100%
540mm 380mm 460mm
20.35Kg
Recommended
Receptacle
NEMA 6-50
NEMA 5-30

Related product manuals