Program Command Description Instrument models on which the
command is valid, parameter ranges,
and supported variables.
LINE MARKER1
***.****THz
Sets line marker 1 to a specified
frequency position (according to
a frequency value).
AQ6370C/AQ6370D
176.5000 to 500.0000 (0.0001 step)
AQ6373/AQ6373B
250.0000 to 856.5000 (0.0001 step)
AQ6375/AQ6375B
60.5000 to 250.0000 (0.0001 step)
LINE MARKER1
***.****cm
-1
Sets line marker 1 to a specified
wavenumber position (according
to a wavenumber value).
AQ6375/AQ6375B
2067.000 to 8333.000 (0.001 step)
LINE
MARKER1@@@@@
Sets line marker 1 to the
wavelength position of vaiable
@@@@@
AQ6370C/AQ6370D
@@@@@: E
1
, G, H, I, J, K, O
1
, P, Q,
R,S, T
1
, U
1
, V
1
, X, Y, Z, WM, W1, W2,
W(CH), MEANWL, PKWL, WDMWL(CH),
NFWL(CH), WAM1, WAM2, WAM3,
WAM4
LINE
MARKER2****.***nm
Sets line marker 2 to a specified
wavelength position (according
to a wavelength value).
AQ6370C/AQ6370D
600.000 to 1700.000 (0.001 step)
AQ6373/AQ6373B
350.000 to 1200.000 (0.001 step)
AQ6375/AQ6375B
600.000 to 2400.000 (0.001 step)
LINE MARKER2
***.****THz
Sets line marker 2 to a specified
frequency position (according to
a frequency value).
AQ6370C/AQ6370D
176.5000 to 500.0000 (0.0001 step)
AQ6373/AQ6373B
250.0000 to 856.5000 (0.0001 step)
AQ6375/AQ6375B
60.0000 to 250.0000 (0.0001 step)
LINE MARKER2
***.****cm
-1
Sets line marker 2 to a specified
wavenumber position (according
to a wavenumber value).
AQ6375/AQ6375B
2067.000 to 8333.000 (0.001 step)
LINE
MARKER2@@@@@
Sets line marker 2 to the
wavelength position of variable
@@@@@
AQ6370C/AQ6370D
@@@@@: E
1
, G, H, I, J, K, O
1
, P, Q,
R, S, T
1
, U
1
, V
1
, X, Y, Z, WM, W1, W2,
W(CH), MEANWL, PKWL, WDMWL(CH),
NFWL(CH), WAM1, WAM2, WAM3,
WAM4
LINE
MARKER3****.***dB
Sets line marker 3 to a specified
level.
–139.90 to 159.90 (0.01 step)
LINE MARKER3
****.***dBm
Sets line marker 3 to a specified
level.
–210.00 to 50.00 (0.01 step)
LINE MARKER3
*.***##
Sets line marker 3 to a specified
level.
1.00pW to 1000mW
(1.00 to 9.99[pW, nW, µW, mW]:
0.01 step
10.0 to 99.9(100) [pW, nW, µW, (mW)]: 0.1
step
100 to 999 [pW, nW, µW, mW]:
1 step)
## is , pW, nW, µW, mW (Select one of
the above)
LINE MARKER3 **.*** Sets line marker 3 to a specified
level.
0.00 to 2500.00 (0.01 step)
LINE
MARKER3@@@@@
Sets line marker 3 to the level
position of variable @@@@@
AQ6370C/AQ6370D
@@@@@: E
1
, G, H, I, J, K, O
1
, P, Q, R,
S, T
1
, U
1
, V
1
, X, Y, Z, LM, L1, L2, L(CH),
PKLVL, WDMLVL(CH), NFLVI(CH),
NFLVO(CH), NFASELV(CH), MKPWR,
LAM1, LAM2, LAM3, LAM4