EasyManua.ls Logo

YOKOGAWA DL350 - Page 35

YOKOGAWA DL350
215 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-8
IM DL350E-17EN
4.1 List of Commands
Command Function page
:CHANnel<x>:STRain:BALance?
Queries the ON/OFF state of target channels when executing balancing
collectively on all channels of a strain module.
4-67
:CHANnel<x1>:STRain:BALance:CHA
Nnel<x2>
Sets or queries the channels that balancing will be performed on for a strain
module.
4-67
:CHANnel<x>:STRain:BALance:EXEC
ute
Executes strain balancing collectively on all strain modules. 4-67
:CHANnel<x>:STRain:BWIDth
Sets or queries the filter of a strain module. 4-67
:CHANnel<x>:STRain:EXCitation
Sets or queries the bridge voltage of a strain module. 4-67
:CHANnel<x>:STRain:GFACtor
Sets or queries the gauge factor of a strain module. 4-67
:CHANnel<x>:STRain:INVert
Sets or queries whether the display is inverted (ON) or not (OFF) for a strain
module.
4-67
:CHANnel<x>:STRain:LSCale?
Queries all the linear scaling settings of a strain module. 4-67
:CHANnel<x>:STRain:LSCale:AVAL
ue
Sets or queries the scaling coefficient A that is used during linear scaling for
a strain module.
4-67
:CHANnel<x>:STRain:LSCale:BVAL
ue
Sets or queries the scaling coefficient B that is used during linear scaling for
a strain module.
4-68
:CHANnel<x>:STRain:LSCale:DISPl
aytype?
Queries all the linear-scaling result display-mode settings of a strain module. 4-68
:CHANnel<x>:STRain:LSCale:DISPl
aytype:DECimalnum
Sets or queries the decimal place that is used when the linear-scaling result
display mode is set to Float for a strain module.
4-68
:CHANnel<x>:STRain:LSCale:DISPl
aytype:MODE
Sets or queries the linear-scaling result display mode of a strain module. 4-68
:CHANnel<x>:STRain:LSCale:DISPl
aytype:SUBunit
Sets or queries the unit prefix that is used when the linear-scaling result
display mode is set to Float for a strain module.
4-68
:CHANnel<x>:STRain:LSCale:GETMe
asure
Executes the measurement of the linear scaling P1:X or P2:X value of a
strain module.
4-68
:CHANnel<x>:STRain:LSCale:MODE
Sets or queries the linear scaling mode of a strain module. 4-68
:CHANnel<x>:STRain:LSCale:{P1X|
P1Y|P2X|P2Y}
Sets or queries the linear scaling P1:X, P1:Y, P2:X, or P2:Y value of a strain
module.
4-69
:CHANnel<x>:STRain:LSCale:SHUNt
Executes shunt calibration. 4-69
:CHANnel<x>:STRain:LSCale:UNIT
Sets or queries the unit string for linear scaling of the strain module. 4-69
:CHANnel<x>:STRain:RANGe
Sets or queries the measurement range of a strain module. 4-69
:CHANnel<x>:STRain:SCALe
Sets or queries the upper and lower limits of the screen for a strain module. 4-69
:CHANnel<x>:STRain:UNIT
Sets or queries the unit of a strain module. 4-69
:CHANnel<x>:TEMPerature?
Queries all settings of a module that can measure temperature. 4-70
:CHANnel<x>:TEMPerature:BURNout
Sets or queries whether burnout will be detected when temperature
measurements are performed.
4-70
:CHANnel<x>:TEMPerature:BWIDth
Sets or queries the bandwidth limit that is used when temperature
measurements are performed.
4-70
:CHANnel<x>:TEMPerature:COUPli
ng
Sets or queries the input coupling setting of a module that can measure
temperature.
4-70
:CHANnel<x>:TEMPerature:DUPeri
od (Data update period)
Sets or queries the date update interval setting of a 16-CH temperature/
voltage input module.
4-70
:CHANnel<x>:TEMPerature:RJC
Sets or queries the RJC that is used when temperature measurements are
performed.
4-70
:CHANnel<x>:TEMPerature:SCALe
Sets or queries the upper and lower limits of the screen that are used when
temperature measurements are performed.
4-70
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:BURNout
Sets or queries whether burnout will be detected when temperature
measurements are performed on a 16-CH temperature/voltage input module.
4-71
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:COUPling
Sets or queries the input coupling setting of a 16-CH temperature/voltage
input module.
4-71
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:LABel
Sets or queries the channel label when temperature measurements are
performed on a 16-CH temperature/voltage input module.
4-71
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:RJC
Sets or queries the RJC when temperature measurements are performed on
a 16-CH temperature/voltage input module.
4-71
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:SCALe
Sets or queries the upper and lower limits on the screen when temperature
measurements are performed on a 16-CH temperature/voltage input module.
4-72
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:TYPE
Sets or queries the thermocouple type to use when temperature
measurements are performed on a 16-CH temperature/voltage input module.
4-72
:CHANnel<x1>:TEMPerature:SCHann
el<x2>:UNIT
Sets or queries the unit when temperature measurements are performed on
a 16-CH temperature/voltage input module.
4-72
:CHANnel<x>:TEMPerature:TYPE
Sets or queries the thermocouple type that is used when temperature
measurements are performed.
4-72

Table of Contents