4.1 List of Commands
Command Function page
:CHANnel<x>:TEMPerature:UNIT
Sets or queries the unit that is used when temperature measurements are
performed.
4-72
:CHANnel<x>:VOLTage?
Queries all settings of a module that can measure analog voltage. 4-73
:CHANnel<x>[:VOLTage]:BWIDth
Sets or queries the bandwidth limit of a module that can measure analog
voltage.
4-73
:CHANnel<x>[:VOLTage]:COUPling
Sets or queries the input coupling of a module that can measure analog
voltage.
4-73
:CHANnel<x>[:VOLTage]:DOCancel?
Queries all DC offset cancellation settings of a voltage measurement
module.
4-73
:CHANnel<x>[:VOLTage]:DOCancel:
EXECute
Executes DC offset canceling on a voltage measurement module. 4-73
:CHANnel<x>[:VOLTage]:DOCancel:
MODE
Sets or queries the on/off status of DC offset canceling of voltage
measurement modules.
4-73
:CHANnel<x>[:VOLTage]:INVert
Sets or queries whether the display is inverted (ON) or not (OFF) for a
module that can measure analog voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale?
Queries all the linear scaling settings of a module that can measure analog
voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale:AV
ALue
Sets or queries the scaling coefficient A that is used during linear scaling for
a module that can measure analog voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale:BV
ALue
Sets or queries the offset value B that is used during linear scaling for a
module that can measure analog voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale:DI
SPlaytype?
Queries all the linear-scaling result display-mode settings of a module that
can measure analog voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale:DI
SPlaytype:DECimalnum
Sets or queries the decimal place that is used when the linear-scaling result
display mode is set to Float for a module that can measure analog voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale:DI
SPlaytype:MODE
Sets or queries the linear-scaling result display mode of a module that can
measure analog voltage.
4-74
:CHANnel<x>[:VOLTage]:LSCale:DI
SPlaytype:SUBunit
Sets or queries the unit prefix that is used when the linear-scaling result
display mode is set to Float for a module that can measure analog voltage.
4-75
:CHANnel<x>[:VOLTage]:LSCale:GE
TMeasure
Executes the measurement of the linear scaling P1:X or P2:X value of a
module that can measure analog voltage.
4-75
:CHANnel<x>[:VOLTage]:LSCale:MO
DE
Sets or queries the linear scaling mode of a module that can measure analog
voltage.
4-75
:CHANnel<x>[:VOLTage]:LSCale:{P
1X|P1Y|P2X|P2Y}
Sets or queries the linear scaling P1:X, P1:Y, P2:X, or P2:Y value of a
module that can measure analog voltage.
4-75
:CHANnel<x>[:VOLTage]:LSCale:UN
IT
Sets or queries the linear-scaling unit string of a module that can measure
analog voltage.
4-75
:CHANnel<x>[:VOLTage]:POSition
Sets or queries the vertical position for a module that can measure analog
voltage.
4-75
:CHANnel<x>[:VOLTage]:PROBe
Sets or queries the probe type of a module that can measure analog voltage. 4-75
:CHANnel<x>[:VOLTage]:SCALe
Sets or queries the upper and lower limits of the screen for a module that
can measure analog voltage.
4-75
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>?
Queries all settings of a 4-CH module, 16-CH voltage input module, or 16-
CH temperature/voltage input module. If the coupling is set to TC on a 16-
CH temperature/voltage input module, a query is made for only the label and
coupling.
4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:BWIDth
Sets or queries the bandwidth limit of a 4-CH module or 16-CH voltage input
module.
4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:COUPling
Sets or queries the input coupling setting of a 4-CH module, 16-CH voltage
input module, 16-CH temperature/voltage input module.
4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:DISPlay
Sets or queries whether the 4-CH module is displayed. 4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:DOCancel?
Queries all DC offset cancellation settings of a 4-CH module. 4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:DOCancel:EXECute
Executes DC offset canceling on a 4-CH module. 4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:DOCancel:MODE
Sets or queries the on/off status of DC offset canceling of 4-CH modules. 4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:INVert
Sets or queries whether the display is inverted (ON) or not (OFF) a 4-CH
module, 16-CH voltage input module, 16-CH temperature/voltage input
module.
4-76
:CHANnel<x1>[:VOLTage]:SCHannel
<x2>:LABel
Sets or queries the label string of the specified sub channel for a 4-CH
module, 16-CH voltage input module, 16-CH temperature/voltage input
module.
4-77