EasyManua.ls Logo

YOKOGAWA EJA210E User Manual

YOKOGAWA EJA210E
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Users
Manual
Contents
1. Introduction
1.1 For Safe Use of Product ..............................................2
1.2 Warranty ......................................................................4
1.3 ATEX Documentation ..................................................5
2. Handling Cautions
2.1 ModelandSpecicationsCheck .................................7
2.2 SelectingtheInstallationLocation ..............................7
2.3 PressureConnection ..................................................7
2.4 InstallationofanExplosion-ProtectedInstrument ......7
2.5 EMCConformityStandards ..................................... 27
2.6 Pressure Equipment Directive (PED) ...................... 28
2.7 Safety Requirement Standards ................................ 29
3. Installation
3.1 Mounting................................................................... 30
3.2
MountingtheDiaphragmSeals ......................................30
3.3 DiaphragmSealsInstallationConsideration ............ 31
3.4 MountingtheFlushingConnectionRing .................. 32
3.5 AfxingtheTeonFilm ............................................. 33
3.6 Rotating Transmitter Section .................................... 34
3.7 ChangingtheDirectionofIntegralIndicator............. 34
4. Installing Impulse Piping
4.1 ImpulsePipingInstallationPrecautions ................... 35
4.2 ImpulsePipingConnectionExamples ..................... 37
4.3 ProcessPipingInstallationPrecautions(EJ115) 38
5. Wiring
5.1 Wiring Precautions ................................................... 40
5.2 ConnectionsofExternalWiringtoTerminalBox ...... 40
5.3 Wiring ....................................................................... 43
5.4 RTDCableConnection(EJX910A/EJX930A) ......... 45
5.5 Grounding ................................................................ 47
5.6 PowerSupplyVoltageandLoadResistance ........... 47
6. Operation
6.1 Preparation for Starting Operation ........................... 48
6.2 Zero Point Adjustment .............................................. 48
6.3 LocalParameterSetting .......................................... 49
7. Errors and Countermeasures
EJX and EJA-E Series
Differential Pressure and
Pressure Transmitters
Installation Manual
IM01C25A01-01E
IM01C25A01-01E
12thEdition
Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA EJA210E and is the answer not in the manual?

YOKOGAWA EJA210E Specifications

General IconGeneral
ModelEJA210E
TypeDifferential Pressure Transmitter
Process Temperature Limits-40 to 120 °C (-40 to 248 °F)
Storage Temperature-40 to 85 °C (-40 to 185 °F)
Output Signal4 to 20 mA DC
Communication ProtocolHART, Foundation Fieldbus
Power Supply10.5 to 42 V DC (HART/BRAIN)
Operating Temperature-40 to 85 °C
Relative Humidity0 to 100% RH
MaterialSUS316L
ProtectionIP67, NEMA 4X
Housing MaterialAluminum alloy
Ambient temperature limits-40 to 85°C (−40 to 185°F)

Summary

Introduction

1.1 For Safe Use of Product

Essential safety guidelines for installation, wiring, operation, and maintenance of the transmitter.

Handling Cautions

2.3 Pressure Connection

Critical safety precautions for connecting impulse piping to the transmitter under pressure.

2.4.1 FM Approval

FM intrinsic safety and nonincendive requirements for HART/BRAIN protocol transmitters in hazardous locations.

2.4.2 CSA Certification

CSA intrinsic safety and nonincendive standards for HART/BRAIN protocol transmitters in hazardous locations.

2.4.3 ATEX Certification

ATEX intrinsic safety and flameproof standards for HART/BRAIN and Fieldbus transmitters in hazardous areas.

2.4.4 IECEx Certification

IECEx intrinsic safety and flameproof standards for HART/BRAIN and Fieldbus transmitters in hazardous areas.

Installation

Installing Impulse Piping

4.1 Impulse Piping Installation Precautions

Key precautions for routing and connecting impulse piping to ensure accurate pressure measurement and safety.

Wiring

5.1 Wiring Precautions

Critical precautions for wiring, including noise reduction, explosion-proof requirements, and sealant application.

Operation

6.2 Zero Point Adjustment

Details the procedure for adjusting the transmitter's zero point using the external adjustment screw.

Errors and Countermeasures

Alarm Message Summary

Lists common alarm messages, their causes, output operations during errors, and suggested countermeasures.

Related product manuals