5
All Rights Reserved. Copyright © 2014, Yokogawa Electric Corporation
GS 04L53B01-01EN Nov. 10, 2015-00
2ch.mode
*2
Sampling interval Integration time
100msormore 16.67ms/20ms
1 s 36.67ms
2sormore 100ms
*1 In10chmode,whenthescanintervalissetto100
msor200ms,theA/Dintegrationtimeisxedat
1.67ms.Thispreventspowerfrequencynoise
frombeingeliminated,causingmeasuredvalues
to wobble.
*2 Cannotbespeciedfortheelectromagnetic
relayscannertype(TypeSufxCode:-T1),Low
withstandvoltagerelaytype(TypeSufxCode:
-L1).
• Calibration correction:
Mode:LinearizerApproximation,LinearizerBias
Numberofcorrectingpoints:12
• Moving average function:
Can be switched On/Off (Settable for each
channel)
Movingaveragenumbercanbeselectedfrom2
to100times
• Referencejunctioncompensation:
Mode: Can be switch internal or external
(Settable for each channel)
(Setthevalueofthecompensationtemperature
at external)
• Input calculation:
Linearscaling,squareroot,differential
calculations (Settable for each channel)
• Bias function:
Can be set the bias value to be added to the
input value (Settable for each channel)
•
Terminaltype:M3screwterminalorClampterminal
• Withstand voltage
Universal,Solidstaterelayscannertype,
Electromagneticrelayscannertype;betweenthe
inputterminalsandtheinternalcircuit:3000V
ACforoneminute
Betweentheanaloginputchannels:1000VACfor
oneminute
Current, Scanner type; between the input
terminalsandtheinternalcircuit:1500VACfor
oneminute
Betweentheanaloginputchannels:1000VAC
foroneminute(excludingb-terminal)
Low withstand voltage type; between the input
terminalsandtheinternalcircuit:1500VACfor
oneminute
Betweentheanaloginputchannels:400VACfor
oneminute(excludingb-terminal)
• Insulation resistance:
Betweentheinputterminalsandtheinternal
circuit:20MΩorgreaterat500VDC
• Recommendedreplacementperiodof
electromagneticrelayscannertypemodules:
Electromagneticrelayscannertypemodules
makemeasurementsbyswitchingmechanical
contact relays on and off.
Toensurethatthemodulescontinuetooperate
reliablyandcorrectly,replacethem
Continuoususeatmeasurementinterval1s:1year
Continuoususeatmeasurementinterval2s:2years
Continuoususeatmeasurementinterval5s:5years
Safety and EMC Standards
• CSA: CSA22.2 No.61010-1, installation category
II
*1
, pollution degree 2
*2
, and CSA-C22.2 NO.
61010-2-030-12
• UL:UL61010-1,UL61010-2-030(CSANRTL/C)
• CE
*3
:
EMC directive
EN61326-1compliance,ClassATable2
EN61000-3-2compliance
EN61000-3-3compliance
EN55011 Class A Group 1
Low voltage directive
EN61010-1, EN 61010-2-030
Installation category II
*1
Pollution degree 2
*2
MeasurementcategoryII
*3
• EMCRegulatoryArrangementinAustraliaand
NewZealand(RCM):EN55011compliance,
Class A Group 1
• KCmarking:Electromagneticwaveinterference
preventionstandard,electromagneticwave
protectionstandardcompliance
*1 Installationcategory(overvoltagecategory)II:
Describesanumberwhichdenesatransient
overvoltage condition.
Impliestheregulationforimpulsewithstandvoltage.
“II”appliestoelectricalequipmentwhich
issuppliedfromthexedinstallationlikea
distribution board.
*2 Pollutiondegree2:
Describesthedegreetowhichasolid,liquid,
or gas which deteriorates dielectric strength or
surface resistivity is adhering.
“2”appliestonormalindooratmosphere.
Normally,onlynon-conductivepollutionoccurs.
*3 TheCEstandardsformodulesrepresent
standardsthataremetwhenthemoduleis
installedinthemainunit.
*4 MeasurementcategoryII(CATII):
Appliestomeasuringcircuitsconnectedtolow
voltageinstallation,andelectricalinstruments
suppliedwithpowerfromxedequipmentsuchas
electric switchboards.
• WEEEDirective:Compliant
Construction
• Frontpanel(terminal):Wateranddust-proof,
ComplieswithIEC529-IP20
• Material: Polycarbonate
• Color;
Front:Charcoalgreylight(CC28)
Bezel:Smokeblue(CC53)
• Dimensions:45.1mm(W)x111mm(H)x133.1
mm(D)(D:includingterminalcover)
• Weight: Approx. 0.3 kg
Power Supply
SuppyfromGX/GP,GX60expandableI/O,GM90PS
powersupplymodule.
• Powerconsumption:
GX90XA-10-U2:0.7Worless
GX90XA-10-T1: 0.9 W or less
GX90XA-10-C1: 0.7 W or less