14-12 IM 760401-01E
Command Description Page
DISPlay Group
:DISPlay<x>? Queries all the display settings. 14-22
:DISPlay<x>:ELEMent Sets/queries the element to be displayed. 14-22
:DISPlay<x>:FUNCtion Sets/queries the function to be displayed. 14-23
:DISPlay<x>:MODE Sets/queries the contents of the display. 14-23
:DISPlay<x>:RESolution Sets/queries the number of display digits. 14-23
HARMonics Group
:HARMonics? Queries all settings related to harmonic measurement. 14-24
:HARMonics:DISPlay? Queries all settings related to the display in case of harmonic measurement. 14-24
:HARMonics:DISPlay:ORDer Sets/queries the order of the harmonic component to be shown
on display B. 14-24
:HARMonics:ELEMent Sets/queries the element for harmonic measurement. 14-24
:HARMonics[:STATe] Sets/queries the harmonic measurement mode ON/OFF. 14-24
:HARMonics:SYNChronize Sets/queries the input to be used as PLL source. 14-25
:HARMonics:THD Sets/queries the computation method for harmonic distortion. 14-25
INTEGrate Group
:INTEGrate? Queries all settings related to integration. 14-25
:INTEGrate:MODE Sets/queries the integration mode. 14-25
:INTEGrate:RESet Resets the integration values. 14-25
:INTEGrate:STARt Starts integration. 14-25
:INTEGrate:STOP Stops integration. 14-25
:INTEGrate:TIMer Sets/queries the integration timer. 14-25
MATH Group
:MATH? Queries all settings related to the computing function. 14-26
:MATH:ARIThmetic Sets/queries the computing equation of the four arithmetic operations. 14-26
:MATH:AVERage Sets/queries the average active power computation during integration. 14-26
:MATH:CFACtor Sets/queries the computing equation of the crest factor. 14-26
:MATH:TYPE Sets/queries the computing equation. 14-27
MEASure Group
:MEASure? Queries all settings related to measurement/computation data. 14-29
:MEASure:HARMonics? Queries all settings related to harmonic measurement data. 14-29
:MEASure:HARMonics:ITEM? Queries all settings related to the output items of harmonic measurement data. 14-29
:MEASure:HARMonics:BINary? Queries harmonic measurement data set by commands other than
“MEASure:HARMonics:ITEM” (binary format). 14-29
:MEASure:HARMonics:ITEM:PRESet Sets the ON/OFF pattern for all communication outputs of the harmonic
measurement function. 14-29
:MEASure:HARMonics:ITEM:{SYNChronize|<harmonic measurement function>}
Sets/queries the communication output item of harmonic measurement ON/OFF. 14-30
:MEASure:HARMonics:VALue? Queries harmonic measurement data set by commands other than
“MEASure:HARMonics:ITEM” (ASCII format). 14-30
:MEASure:HEADer Turns ON/OFF the additional information output when outputting
measured/computed data in binary format. 14-30
:MEASure:NORMal? Queries all settings related to normal measured/computed data. 14-30
:MEASure[:NORMal]:BINary? Queries normal measurement data set by commands other than
“MEASure[:NORMal]:ITEM” (binary format). 14-30
:MEASure[:NORMal]:ITEM? Queries all settings related to the output items of normal
measured/computed data. 14-30
:MEASure[:NORMal]:ITEM:PRESet Sets the ON/OFF pattern for all communication outputs of the normal
measurement function. 14-31
14.3 Commands