14-41
IM 760401-01E
Communication Commands 2 (System of Commands Complying to the IEEE 488.2-1992 Standard)
14
STATus:QMESsage
Function Sets whether or not to apply the corresponding
message to the query “STATus:ERRor?
queries the current setting.
Syntax STATus:QMESsage {<Boolean>}
STATus:QMESsage?
Example STATUS:QMESSAGE OFF
STATUS:QMESSAGE? -> :STATUS:
QMESSAGE 0
STATus:SPOLL?(Serial Poll)
Function Executes serial polling.
Syntax STATus:SPOLL?
Example STATUS:SPOLL? -> STATUS:SPOLL 0
Description This command is used for the serial interface.
An interface message is available for the GP-IB
interface.
14.3.14 STORe Group
The commands in the STORe group are used to make settings relating to and inquiries about storing data. This
allows you to make the same settings as when using the lower menus of [MEMORY]-“StorE” or [MEMORY]-“PnLSt”.
:STORe :STAT e <Space> OFF
ON
<NRf>
?
INTer v
al <Space> <NRf> , <NRf> , <NRf>
?
PANel <Space> <NRf>
?
<Character string>
;
STORe[:STATe]
Function Sets store ON/OFF, queries the current setting.
Syntax STORe[:STATe] {<Boolean>}
STORe:STATe?
Example STORE:STATE ON
STORE:STATE? -> :STORE:STATE 1
14.3 Commands
STORe?
Function Queries all settings related to storing data.
Syntax STORe?
Example STORE? -> :STORE:STATE 0;
INTERVAL 0,0,0
STORe:INTerval
Function Sets the interval for storage/queries the current
setting.
Syntax STORe:INTerval {<NRf>,<NRf>,<NRf>|
<String>}
STORe:INTerval?
{<NRf>,<NRf>,<NRf>}=0,0,0 to 99,59,59
{<String>}=HH:MM:SS HH hours MM
minutes SS seconds
Example STORE:INTERVAL 0,0,0
STORE:INTERVAL “00:00:00“
STORE:INTERVAL?
-> :STORE:INTERVAL 0,0,0
Description If the store interval is set to 0 h 0 min 0 s, the
store interval is set to the same interval as the
display update rate.
STORe:PANel
Function Saves the setup parameters to a file.
Syntax STORe:PANel {<NRf>}
{<NRf>}=1 to 4:file number
Example STORE:PANEL 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA WT210 and is the answer not in the manual?

YOKOGAWA WT210 Specifications

General IconGeneral
BrandYOKOGAWA
ModelWT210
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals