Do you have a question about the YSI ProDSS and is the answer not in the manual?
Conductivity Range | 0 to 200 mS/cm |
---|---|
Power Supply | Rechargeable lithium-ion battery |
Waterproof Rating | IP67 |
Measurement Parameters | Dissolved Oxygen, Conductivity, pH |
Dissolved Oxygen Range | 0 to 50 mg/L; 0 to 500 % saturation |
pH Range | 0 to 14 |
Temperature Range | -5 to +50°C |
Display | Color display with backlight |
Data Logging | Up to 100, 000 data sets |
Connectivity | USB, Bluetooth |
Battery Life | Approximately 48 hours |
Guidelines for safe operation and potential hazards.
Explanation of symbols used to denote warnings and notes.
Details on the instrument's parts and accessories.
Information on battery operation, lifespan, and optimization.
Procedure for charging the instrument's battery pack.
Step-by-step guide for replacing the battery pack.
Instructions for connecting the handheld to sensor cable assemblies.
Procedure for installing and removing sensors from the bulkhead.
Guide for attaching sensor guards and weights for stability.
Details on using sensor guard weights for deep profiling.
Description of the instrument's keypad and navigation controls.
Instructions for turning the instrument on and off.
How to navigate through the instrument's menus and options.
Explanation of the information shown on the main display screen.
Accessing and adjusting instrument settings via the System menu.
Setting the date and time for accurate data logging.
Managing Good Laboratory Practice (GLP) data records.
Configuring GLP file identification options.
Setting reminders for sensor recalibration.
Password protection for calibration settings.
Selecting the instrument's display language.
Choosing between comma or decimal for numeric displays.
Configuring data logging settings like site and data IDs.
Setting automatic or manual sampling modes.
Configuring automatic instrument power-off to save battery.
Adjusting screen and keypad backlight settings.
Viewing the instrument's software version.
Displaying the instrument's serial number.
Setting a unique identifier for the instrument.
Viewing detailed hardware and software information for system components.
Adjusting screen brightness for optimal viewing.
Accessing sensor settings, display, auto-stable, and GPS options.
Configuring settings for installed sensors.
Configuring Optical Dissolved Oxygen (ODO) measurements.
Setting Total Suspended Solids (TSS) coefficients for turbidity.
Configuring pH calibration settings (USA or NIST).
Setting temperature reference, TDS constant for conductivity.
Configuring depth offset, altitude, and latitude for depth sensor.
Determining which measurements appear on the Run screen.
Enabling and configuring automatic measurement stability detection.
Understanding salinity measurement and recommendations.
Turning the Global Positioning System (GPS) on or off.
Accessing logged data, GLP files, and backup options.
Steps for preparing and taking accurate measurements.
Accessing and navigating the calibration menu.
Preparation steps before calibrating sensors.
General setup for calibrating various sensor types.
Instructions for installing and using the calibration cup.
Information on conductivity sensor and its calibration.
Information on barometer calibration and usage.
Procedures for calibrating dissolved oxygen measurements.
Steps for calibrating dissolved oxygen in mg/L.
Procedure for performing a zero point calibration for ODO.
Guide for performing a single-point pH calibration.
Steps for performing multi-point pH calibrations.
Procedure for calibrating the Oxidation-Reduction Potential (ORP) sensor.
Instructions for calibrating the depth sensor.
Information on turbidity sensor calibration standards and limits.
Detailed steps for multi-point turbidity calibration.
Overview of ISE sensor calibration, mV info, and standards.
Procedure for performing a three-point ISE calibration.
Guidance for using a chilled solution in 3-point ISE calibration.
Recipes for preparing chloride calibration standards.
Recipes for preparing nitrate calibration standards.
Recipes for preparing ammonium calibration standards.
Maintenance and storage procedures for the handheld device.
Maintenance and storage for cables, bulkheads, and connectors.
Maintenance and cleaning of the sensor guard.
Procedures for maintaining and storing the depth sensor.
Maintenance and storage guidelines for the turbidity sensor.
Maintenance and storage for the conductivity/temperature sensor.
Maintenance, cleaning, and replacement of ODO sensor caps.
Detailed steps for replacing the ODO sensor cap.
Entering new calibration coefficients for ODO sensor caps.
Maintenance procedures for pH and pH/ORP sensors.
Storage guidelines for pH and pH/ORP sensors.
Maintenance for Ammonium, Nitrate, and Chloride sensors.
Short-term storage for ISE sensors.
Long-term storage for ISE sensors.
Procedure for replacing sensor modules (pH, ORP, ISE).
Hardware and software requirements for KorDSS installation.
Step-by-step guide to install the KorDSS software.
Instructions for installing the ProDSS instrument driver.
Specific driver installation for Windows XP.
Specific driver installation for Windows 7.
Wizard to set up KorDSS language and licensing.
Information on how to order accessories and contact YSI.
List of available ProDSS handheld models.
List of ProDSS cable assemblies by length and type.
List of ODO/OBOD sensor and cable assemblies.
List of available ProDSS smart sensors.
List of replacement sensor modules and ODO sensor caps.
List of carrying cases, chargers, cables, maintenance kits, and other accessories.
List of available calibration standards for various sensors.
Crucial safety guidelines for handling and using the Li-Ion battery.
Safe practices for charging, discharging, and handling the battery pack.
Details on product warranty coverage, limitations, and claims procedures.