EasyManuals Logo
Home>Zapi>Inverter>ACE3

Zapi ACE3 User Manual

Zapi ACE3
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Page – 22/139 AFFZP0BB – ACE3 – User Manual
Connector B
B1 PEV Connect the positive supply of electrovalves (EV1, EV2,
EV3, EV4, EV5) to this pin. Take the positive supply
immediately after the main contactor.
B2 CPOT EVP Proportional-valve-potentiometer input (wiper contact).
B3 ANIN5 Free analog input.
B4 AUX1 Free digital input, active when connected to -Batt
B5 AUX2 Free digital input, active when connected to -Batt.
B6 BACKING FW Forward-inching-request input. It must be connected to
the forward-inching microswitch, active high.
B7 SH1/SIN First Hall-sensor input, active low. Using a special
hardware configuration it is possible to use it for the sin
signal of a sin/cos sensor.
B8 PSENS Positive supply 12 V / 5 V for Hall sensors or sin/cos
sensor.
B9 NEV5 Output for the voltage-controlled PWM-modulated EV5
electrovalve; 1 A maximum continuous current (driving to
-Batt). Freewheeling diode to B1 is built-in.
B10 STEER POT Steering-potentiometer input (from wiper contact).
B11 AUX3 Braking-request input. It must be connected to the brake
pedal microswitch, active high.
B12 CAN_T2 CAN termination. If it is connected to B21 (CAN_H2) it
introduces the 120 Ohm termination resistance between
CAN_L2 and CAN_H2.
B13 BACKING BW Backward-inching-request input. It must be connected to
the backward-inching microswitch, active high.
B14 SH2/COS Second Hall-sensor input, active low. Using a special
hardware configuration it is possible to use it for the cos
signal of a sin/cos sensor.
B15 NSENS Negative supply for Hall sensors (or sin/cos sensor).
B16 NEV1 Output for the voltage-controlled PWM-modulated EV1
electrovalve; 1 A maximum continuous current (driving to
-Batt). Freewheeling diode to B1 is built-in.
B17 NEV2 Output for the voltage-controlled PWM-modulated EV2
electrovalve; 1 A maximum continuous current (driving to
-Batt). Freewheeling diode to B1 is built-in.
B18 NEV3 Output for the voltage-controlled PWM-modulated EV3
electrovalve; 1 A maximum continuous current (driving to
-Batt). Freewheeling diode to B1 is built-in.
B19 NEV4 Output for the voltage-controlled PWM-modulated EV4
electrovalve; 1 A maximum continuous current (driving to
-Batt). Freewheeling diode to B1 is built-in.
B20 CAN_L2 CAN bus 2 low-level signal.
B21 CAN_H2 CAN bus 2 high-level signal.
B22 SH3 Third Hall-sensor input, active low.
B23 FREE Free pin.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi ACE3 and is the answer not in the manual?

Zapi ACE3 Specifications

General IconGeneral
BrandZapi
ModelACE3
CategoryInverter
LanguageEnglish

Related product manuals