81
Shift_JIS - Shift Japanese Industrial Standards (JIS) is a character encoding for the Japanese
language.
GB18030 - Chinese coded character set that defines the required language and character support
necessary for software in China.
1D Quiet Zone Level - Sets the level of aggressiveness in decoding barcodes with a reduced quiet zone
(the area in front of and at the end of a barcode), and applies to symbologies enabled by a Reduced Quiet
Zone parameter. Because higher levels increase the decoding time and risk of misdecodes, Zebra strongly
recommends enabling only the symbologies which require higher quiet zone levels, and leaving Reduced
Quiet Zone disabled for all other symbologies.
Options are:
0 - The scanner performs normally in terms of quiet zone.
1 - The scanner performs more aggressively in terms of quiet zone (default).
2 - The scanner only requires one side EB (end of barcode) for decoding.
3 - The scanner decodes anything in terms of quiet zone or end of barcode.
Adaptive Scanning - When adaptive scanning is enabled, the scan engine toggles between wide and
narrow, allowing the scan engine to decode barcodes based on the distance.
Disable
Enable (default).
Beam Width - Beam Width is applicable only with linear scanners.
Narrow
Normal (default)
Wide
Aim mode - Turns the scanner cross-hairs on or off.
On - Cross-hair is on (default).
Off - Cross-hair is off.
Aim Timer - Sets the maximum amount of time that aiming remains on (0 - 60,000 ms in increments of 100
ms). A value of 0 sets the aim to stay on indefinitely (default - 500).
Aim Type - Set the aiming usage.
Trigger - A trigger event activates decode processing, which continues until the trigger event ends or a
valid decode occurs (default).
Timed Hold - A trigger pull and hold activates the laser for aiming, which continues until the trigger is
released, a valid decode, or the decode session time-out is expired.
Timed Release - A trigger pull activates the laser for aiming, which continues until a valid decode or the
remaining decode session time has expired.
Press and Release - A trigger pull and release activates the laser for aiming, which continues until a
trigger is pressed again, a valid decode, or the decode session time-out is expired.
Continuous Read - When the imager detects an object in its field of view, it triggers and attempt to
decode.
Press and Sustain - A trigger pull activates the laser for aiming, which continues until the Beam Timer
expires or a valid decode.
Beam Timer - Sets the maximum amount of time that the reader remains on (0 - 60,000 ms in increments
of 100 ms). A value of 0 sets the reader to stay on indefinitely (default -5000).
Time Delay to Low Power - Sets the time the decoder remains active after decoding. After a scan session,
the decoder waits this amount of time before entering Low Power Mode. Options: 1 Second (default), 30
Seconds, 1 Minute or 5 Minutes.