Troubleshooting
110
Manual Calibration
Manual calibration is recommended whenever you are using pre-printed media or if the printer will not
correctly auto calibrate.
1. Make sure media is loaded. A good common label size is 4 by 6 inches.
2. Turn on the printer power.
3. Send the following command to the printer: ! U1 do "ezpl.manual_calibration" ""
See Sending Files to the Printer.
4. The printer will set the media sensor for the label backing being used. After it is done making this
adjustment, the roll will automatically feed until a label is positioned at the printhead. A profile of the
media sensor settings (similar to the example below) will print. Upon completion, the printer will save
the new settings in memory and the printer is ready for normal operation.
Start of several labels
End of several labels