EasyManua.ls Logo

ZinWave UNITIVITY 5000 - Rohs Information

ZinWave UNITIVITY 5000
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © 2022 Zinwave. All rights reserved. xviii
1
E-UTRA (FDD)
40
2300-2400
2300-2400
E-UTRA (TDD)
7
2620 2690
2500 2570
E-UTRA (FDD)
38
2570 - 2620
2570 - 2620
E-UTRA (TDD)
The 306-XXXX system complies with the Radio Equipment Directive, 2014/53/EU for operation in the
following bands with maximum antenna port power of +22dBm:
Band
Downlink
Frequency (MHz)
Uplink Frequency
(MHz)
Service
N77
3300 4200 [1]
3300 - 4200
5G / NR
N78
3400 - 3800
3400 - 3800
5G / NR
LTE 22
3510 3590
3410 3490
E-UTRA (FDD)
LTE 42
3400 - 3600
3400 - 3600
E-UTRA (TDD)
LTE 43
3600 - 3800
3600 - 3800
E-UTRA (TDD)
Note [1] : Approvals testing performed on 10 May 2021 covered 3400 3800 MHz, but current hardware is
designed to meet 3300 4200 MHz. Further certification is ongoing.
Compliance with national licensing requirements and COMMISSION IMPLEMENTING DECISION (EU)
2019/235.
Operation is subject to the following limits
3410 MHz < F < 3800MHz: EIRP < -34dBm/5MHz = (-41dBm/1MHz
F < 3390 MHz: EIRP < -50dBm/MHz
When a single channel is transmitting at 22 dBm, the maximum in-band “antenna gain + cable loss” is 4.5
dBi
The out of band noise floor below 3390 MHz is typically:
-53.7 dBm for 22 dBm total output power
-56.3 dBm for 17 dBm total output power