Chapter 3 Hardware Panels
XS1930 Series User’s Guide
37
Figure 17 Opening the Transceiver’s Latch Example
Figure 18 Transceiver Removal Example
3.2 Rear Panel
The following figures show the rear panels of the Switch. The rear panels contain:
Figure 19 Rear Panel: XS1930-10
Figure 20 Rear Panel: XS1930-12HP
Figure 21 Rear Panel: XS1930-12F
3.2.1 Grounding
Grounding is a safety measure to direct excess electric charge to the ground. It prevents damage to
the Switch, and protects you from electrocution. Use the grounding screw on the rear panel and the
ground wire of the AC power supply to ground the Switch.
The grounding terminal and AC power ground where you install the Switch must follow your country’s
regulations. Qualified service personnel must ensure the building’s protective earthing terminals are
valid terminals.
Installation of Ethernet cables must be separate from AC power lines. To avoid electric surge and
electromagnetic interference, use a different electrical conduit or raceway (tube/trough or enclosed