20
I CLS
-
LMI
-
Calibration
I
ENGLISH
5.3 Password Setting
Three different level of passwords in order to protect the system by unauthorized personnel.
The first is dedicated to the Technical Personnel just to replace sensors, the second one is dedicated to the Service
Personnel. Both of them can be settled by the Manufacturer.
The 3rd password is for the programming Engineers only.
PROCEDURES STATUS
IN THE CONTROL AREA
Switch machine on and wait for a few seconds until the first starting page shows up on
display as indicated here.
Quickly press once key.
V. xxx
MACHINE MODEL
At this point the page of 1st PASSWORD setting must show up as indicated here.
If different page appears, this means that Key has been
depressed too early or too late: switch system off and re-start.
*
Code: 4477
Press some times the
key to scroll the asterisk above the desired figure and
modify its value by means of
keys.
Confirm it and the following ones (PASSWORD) by . (see also 3.7 par.).
The PASSWORD code is memorised into the EPROM together with the machine
data; its number must be known only by Authorised Personnel.
*
Code: XXXX
Then you enter in Main Screen Visualization - OPERATIVE MODE.
Select the Operative Mode (see 3.1 par.).
Then on the display the main data page is shown as indicated here.
If the main unit is new, it might indicates the Alarm “1”: this, before machine calibration
is normal procedures, but it should disappear at the first “SAVE” function.
If other alarms occur, it is necessary to clean them up before continuing.
Alarm : xx
Code: x