208 CHAPTER 16: MANAGING SYSTEM LOGS
Critical — The third highest warning level. A critical log is saved if a
critical device malfunction occurs; for example, two device ports
are not functioning, while the rest of the device ports remain
functional.
Error — A device error has occurred, for example, if a single port is
offline.
Warning — The lowest level of a device warning. The device is
functioning, but an operational problem has occurred.
Notice — Provides device information.
Info — Provides device information.
Debug — Provides debugging messages.
Enable Syslogging — Specifies if device logging to remote Syslogs
servers is enabled.
Severity level — Specifies the minimum severity level for which a
message will be logged. When a severity level is selected, all severity
level choices above the selection are selected automatically. The
possible field values are identical to those used for Local Logging.
Syslog IP Address — Defines the IP Address of a syslog server to
which syslog messages are sent.
Syslog Port — Defines the UDP Port on the syslog server to which
syslog messages are sent. The range for this field is 1-65535, and the
default is 514.
2 Define the fields.
3 Click. The log parameters are set, and the device is updated.