1-6
To do… Use the command… Remarks
Enable the remote-ping
client function
remote-ping-agent enable
Required
By default, the remote-ping client
function is disabled.
Create a remote-ping
test group and enter its
view
remote-ping
administrator-name
operation-tag
Required
By default, no test group is configured.
Configure the source
interface
source-interface
interface-type
interface-number
Required
You can only configure a VLAN interface
as the source interface.
By default, no source interface is
configured.
Configure the test type
test-type dhcp
Required
By default, the test type is ICMP.
Configure the number
of probes per test
count times
Optional
By default, each test makes one probe.
Configure the
maximum number of
history records that can
be saved
history-records number
Optional
By default, the maximum number is 50.
Configure the probe
timeout time
timeout time
Optional
By default, a probe times out in three
seconds.
Start the test
test-enable
Required
Display test results
display remote-ping results
[ admin-name operation-tag ]
Required
You can execute the command in any
view.
3) Configuring FTP test on remote-ping client
Follow these steps to configure FTP test on remote-ping client:
To do… Use the command… Remarks
Enter system view
system-view
Enable the remote-ping
client function
remote-ping-agent enable
Required
By default, the remote-ping client
function is disabled.
Create a remote-ping
test group and enter its
view
remote-ping
administrator-name
operation-tag
Required
By default, no test group is configured.
Configure the
destination IP address
destination-ip ip-address
Required
By default, no destination address is
configured.
Configure the source IP
address
source-ip ip-address
Required
By default, no source IP address is
configured.
Configure the source
port
source-port port-number
Optional
By default, no source port is configured.