G1 Introduction to AC500 1-60 AC500 / Issued: 07.2006
well as the S500 User's manual for additional installation requirements
pertaining to this equipment.
Before starting
Use this document as a guide for installing and powering-up your S500-FBP Interface Module. You
should already be familiar with the system components.
How to handle S500-FBP components
ATTENTION
Preventing Electrostatic Discharge
This equipment is sensitive to electrostatic discharge, which can cause internal
damage and affect normal operation. Follow these guidelines when you handle
this equipment:
Touch a grounded object to discharge potential static.
Wear an approved grounding wrist strap.
Do not touch connectors or pins on component boards.
Do not touch circuit components inside the equipment.
If available, use a static-safe workstation.
When not in use, store the equipment in appropriate static-safe
packaging.
Make sure that you have all the components you need
To use the S500-FBP Interface Module you should use at least the following parts:
Part Number Designation
1SAP220000R0001 DC505-FBP, Interface Module with 8DI/8DC 24 V DC
1SAP210000R0001 or
1SAP212000R0001
TU505, FBP Terminal Unit with screw or TU506, FBP Terminal Unit with
spring
See the FBP Catalog FieldBusPlug module with desired Fieldbus protocol
You may also use these components with the S500-FBP Interface:
If you want to: Then use this component:
connect a 24 V dc digital sensor or
actuator to the device
DI524 (32 DI ), DC522 (16DC), DC523 (24DC),
DC532 (16DI/16DC) or DX522 (8DI/8 DO-R) with
the corresponding terminal unit with screw-type or
spring connection TU515/516 or TU531/532
connect a 115-230 V AC digital sensor or
actuator to the device
DX531 (8DI 115-230 V AC / 4 DO-R) +
corresponding Terminal Unit TU531/532 with
screw or spring technology
connect a 24 V DC analog sensor or
actuator to the device
AI523 (16AI U/I/PT100), AO523 (16AO),
AX521(4AI/4AO U/I/PT100) or AX522 (8AI/8AO
U/I/PT100) + corresponding Terminal Unit
TU515/516
Label the I/O Channels
TA523 (Pluggable marking holder) + TA525
Markers for marking holder.