FOXCST REFERENCE
36 FOX61xLEDE1
8.3.3.1 AP: / unit-x / port-y, Configuration - General
Table 10: AP: / unit-x / port-y, Configuration - General
Operation Name Parameter Name Range Description / Details
Termination Mode Transparent
Clock and data transparent.
Unstructured 2048 kbit/s signal.
Clock Master
Transparent data, clock locked to PETS.
Unstructured 2048 kbit/s signal.
PCM30
Terminated with CAS, without CRC4.
ITU-T G.704 structured 2048 kbit/s signal.
PCM30C
Terminated with CAS and CRC4.
ITU-T G.704 structured 2048 kbit/s signal.
PCM31
Terminated without CAS or CRC4.
ITU-T G.704 structured 2048 kbit/s signal.
PCM31C
Terminated without CAS, with CRC4.
ITU-T G.704 structured 2048 kbit/s signal.
V5 Uplink
Transport mode for V5 links.
The 5 Sa bits (timeslot 0, spare bits Sa4 … Sa8)
support V5.x applications.
This uplink uses CRC4.
V5 Uplink NCI
Transport mode for V5 links.
The 5 Sa bits (timeslot 0, spare bits Sa4 … Sa8)
support V5.x applications.
This uplink does not offer CRC4.
Switching Bidirectional
In the bidirectional mode the path selector is
controlled by the failure state of the working and
the protecting paths and by the remote selector
state. In the bidirectional switching mode the
local and the remote path selectors are synchro-
nised to select both the same path, i.e. both
select the working path or both select the pro-
tecting path.
Please
refer to "1KHW002467 FOX61x TDM
Services"
for a description of the switching crite-
ria.
In the unidirectional mode the path selector is
controlled by the failure state of the working and
the protecting paths.