Operation Manual / 4 Product description / A100-M axial
Page 35 /
© Copyright 2016 ABB. All rights reserved.
Expected replacement intervals [h]
Gas inlet casing 50000 … 100000 25000 … 50000
Gas outlet casing 50000 … 100000 35000 … 100000
Nozzle ring 35000 … 50000 25000 … 50000
Turbine diffuser / cover ring 35000 … 50000 25000 … 50000
Other casings 100000 100000
Turbine blades (due to wear) - - ≥ 12000
Table 8: Expected replacement intervals
MDO = Marine Diesel Oil
HFO = Heavy Fuel Oil
Recommended replacement intervals [h]
Bearings See rating plate data
Table 9: Recommended replacement intervals
The specified values are guideline values and not guaranteed values, see Influencing parameters.
In the turbocharger, the heat from the lubricating oil that continues to circu-
late must be dissipated.
Let the engine continue to run at idling speed for 10 minutes before stop-
ping it.
Post-lubrication can be used instead of engine idling (Pre-lubrication and
post-lubrication [➙ 19]).