EasyManua.ls Logo

ABB HT568964 - Stopping the Engine; Table 8: Expected Replacement Intervals; Table 9 Recommended Replacement Intervals

ABB HT568964
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / A100-M axial
5
Operation and service
Page 35 /
113
© Copyright 2016 ABB. All rights reserved.
HZTL4033_EN
Revision A
July 2016
Expected replacement intervals [h]
Component
GAS / MDO
HFO
Gas inlet casing 50000 … 100000 25000 … 50000
Gas outlet casing 50000 … 100000 35000 … 100000
Nozzle ring 35000 … 50000 25000 … 50000
Turbine diffuser / cover ring 35000 … 50000 25000 … 50000
Other casings 100000 100000
Turbine blades (due to wear) - - 12000
Table 8: Expected replacement intervals
GAS = Gas
MDO = Marine Diesel Oil
HFO = Heavy Fuel Oil
Recommended replacement intervals [h]
Rotor components
See rating plate data
Bearings See rating plate data
Table 9: Recommended replacement intervals
The specified values are guideline values and not guaranteed values, see Influencing parameters.
5.4 Stopping the engine
CAUTION
Stopping the engine
In the turbocharger, the heat from the lubricating oil that continues to circu-
late must be dissipated.
Let the engine continue to run at idling speed for 10 minutes before stop-
ping it.
Post-lubrication can be used instead of engine idling (Pre-lubrication and
post-lubrication [➙ 19]).

Table of Contents