depending on the parameter settings. Additionally, the selected signals from different
functions and few binary inputs are also connected.
RDRE1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
TRIGGERED
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
OR6
B1
B2
B3
B4
B5
B6
O
CCBRBRF1_TRBU
X120_BI2_CB_CLOSED
X120_BI3_CB_OPENED
DARREC1_CLOSE_CB
PHIPTOC1_OPERATE
PHLPTOC1_OPERATE
PHHPTOC1_OPERATE
NSPTOC1_OPERATE
PHHPTOC2_OPERATE
NSPTOC2_OPERATE
EFPADM1_OPERATE
EFPADM2_OPERATE
EFPADM3_OPERATE
INTRPTEF1_OPERATE
PDNSPTOC1_OPERATE
ROVPTOV1_OPERATE
ROVPTOV2_OPERATE
ROVPTOV3_OPERATE
DEFHPDEF1_OPERATE
DEFLPDEF1_OPERATE
DEFLPDEF2_OPERATE
EFHPTOC1_OPERATE
WPWDE1_OPERATE
WPWDE2_OPERATE
WPWDE3_OPERATE
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
CCBRBRF1_TRRET
PHLPTOC1_START
PHHPTOC1_START
PHHPTOC2_START
PHIPTOC1_START
NSPTOC1_START
NSPTOC2_START
INTRPTEF1_START
EFHPTOC1_START
PDNSPTOC1_START
ROVPTOV1_START
ROVPTOV2_START
ROVPTOV3_START
DEFHPDEF1_START
DEFLPDEF2_START
DEFLPDEF1_START
EFPADM1_START
EFPADM2_START
EFPADM3_START
WPWDE1_START
WPWDE2_START
WPWDE3_START
X120_BI1_EXT_OC_BLOCKING
T1PTTR1_START
INRPHAR1_BLK2H
T1PTTR1_OPERATE
DARREC1_INPRO
ARCSARC1_ARC_FLT_DET
ARCSARC2_ARC_FLT_DET
ARCSARC3_ARC_FLT_DET
DARREC1_UNSUC_RECL
DISTURB_RECORD_TRIGGERED
GUID-9490DCA4-54F2-4490-990B-F9CB5419CACD V2 EN
Figure 71: Disturbance recorder
3.4.3.3 Functional diagrams for condition monitoring
Circuit-breaker condition monitoring SSCBR1 supervises the switch status based on
the connected binary input information and the measured current levels. SSCBR1
introduces various supervision methods.
Set the parameters for SSCBR1 properly.
SSCBR1
BLOCK
POSOPEN
POSCLOSE
OPEN_CB_EXE
CLOSE_CB_EXE
PRES_ALM_IN
PRES_LO_IN
SPR_CHR_ST
SPR_CHR
RST_IPOW
RST_CB_WEAR
RST_TRV_T
RST_SPR_T
TRV_T_OP_ALM
TRV_T_CL_ALM
SPR_CHR_ALM
OPR_ALM
OPR_LO
IPOW_ALM
IPOW_LO
CB_LIFE_ALM
MON_ALM
PRES_ALM
PRES_LO
OPENPOS
INVALIDPOS
CLOSEPOS
CB_CLOSE_COMMAND
CB_OPEN_COMMAND
X120_BI2_CB_CLOSED
X120_BI3_CB_OPENED
X110_BI3_GAS_PRESSURE_ALARM
X110_BI4_CB_SPRING_CHARGED
CB_SPRING_DISCHARGED
SSCBR1_TRV_T_OP_ALM
SSCBR1_TRV_T_CL_ALM
SSCBR1_SPR_CHR_ALM
SSCBR1_OPR_ALM
SSCBR1_OPR_LO
SSCBR1_IPOW_ALM
SSCBR1_IPOW_LO
SSCBR1_CB_LIFE_ALM
SSCBR1_MON_ALM
SSCBR1_PRES_ALM
SSCBR1_PRES_LO
GUID-D287CC35-A7E0-4780-BA09-377C8406B828 V1 EN
Figure 72: Circuit-breaker condition monitoring function
1MRS756378 S Section 3
REF615 standard configurations
REF615 87
Application Manual