22. Ordering for customized IED
Table 123. General guidelines
Guidelines
Carefully read and follow the set of rules to ensure problem-free order management.
Please refer to the available functions table for included application functions.
PCM600 can be used to make changes and/or additions to the delivered factory configuration of the pre-configured.
Table 124. Example ordering code
To obtain the complete ordering code, please combine code from the selection tables, as given in the example below.
The selected qty of each table must be filled in, if no selection is possible the code is 0
Example of a complete code: RET670*2.0-F00X00 - A00002260300001 - B5225255211252221111000001 - C0000888322260002221620300 - D33320010 - E66600 -
F9 - S6 - G542 - H06000014444 - K00000110 - L01 - M186 - P01 - B1X0 - AC - KB - B - A3X0 - D1D1ARGN1N1XXXXXXX -AAFXXX - AX
Product definition - Differential protection -
RET670* 2.0 - X00 - A 0 0 0 0 0 0 0 0 0 -
Impedance protection -
B 0 0 0 0 -
Current protection -
C 0 0 0 0 0 0 -
Voltage protection - Frequency protection - Multipurpose
protection
- General
calculation
-
D 0 0 - E 00 - F - S -
Secondary system supervision - Control -
G - H 0 0 0 0 0 -
Scheme communication - Logic - Monitoring - Station communication -
K 0 0 0 0 0 0 - L - M 0 - P 0 1 -
Langu
age
- Casing
and
Mountin
g
- Conne
ction
and
power
- H
M
I
- Analog input - Binary input/output -
B
1
- - - - - -
Remote end serial communication - Serial communication unit for station communication
-
Table 125. Product definition
RET670*
2.0 X00
Table 126. Product definition ordering codes
Product
RET670*
Software version 2.0
Configuration alternatives
RET670 Transformer protection F00
RET670 61850-9-2LE Transformer protection N00
Selection:
ACT configuration
No ACT configuration downloaded X00
Table 127. Differential protection
Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A 0 0 0 0 0 0 0 0 0
Transformer protection RET670 2.0
1MRK 504 141-BEN C
Product version: 2.0
104 ABB

Table of Contents

Other manuals for ABB RET670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RET670 and is the answer not in the manual?

ABB RET670 Specifications

General IconGeneral
Rated Frequency50/60 Hz
InputsAnalog and binary inputs
ApplicationProtection of power systems
Communication ProtocolsIEC 61850, DNP3, Modbus
Operating Temperature Range-25°C to +55°C
MountingRack mounted
Number of Binary InputsUp to 48
Number of Binary Outputs32
Protection FunctionsOvercurrent Protection
OutputsBinary outputs
EnclosureIP 54
TypeLine Differential Protection
Number of Analog Inputs24